A discriminative measure for static postural control ability to prevent in-hospital falls: Reliability and validity of the Standing Test for Imbalance and Disequilibrium (SIDE)

Toshio Teranishi, Izumi Kondo, Shigeru Sonoda, Hitoshi Kagaya, Yosuke Wada, Hiroyuki Miyasaka, Genichi Tanino, Wataru Narita, Hiroaki Sakurai, Makoto Okada, Eiichi Saitoh

Japanese Journal of Comprehensive Rehabilitation Science · 2010

DOI: 10.11336/jjcrs.1.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Comprehensive Rehabilitation Science, 2010. Verfasst von Toshio Teranishi und 10 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Teranishi T, Kondo I, Sonoda S, Kagaya H, Wada Y, Miyasaka H, Tanino G, Narita W, Sakurai H, Okada M, Saitoh E. A discriminative measure for static postural control ability to prevent in-hospital falls: Reliability and validity of the Standing Test for Imbalance and Disequilibrium (SIDE). Jpn J Compr Rehabil Sci 2010; 1: 11-16Purposes: To determine the reliability, validity, and clinical significance of the Standing Test for Imbalance and Disequilibrium (SIDE), a discriminative measure of standing balance, before using it to prevent falls in clinical settings.

Methods

In all, 30 patients (18 men and 12 women) with a mean (standard deviation) age of 57.4 (16.97) years (range, 25-85 years) who were admitted to the “Kaifukuki” rehabilitation ward voluntarily participated in this study. In the reliability study, 2 physiotherapists independently classified the level of static postural control ability by using SIDE. Functional balance control ability was simultaneously evaluated using the Berg Balance Scale (BBS). Cohen's κ statistic was used to determine the inter-rater reliability, and the Spearman rank-correlation coefficient between the BBS score and SIDE level was used to determine the criterion-related validity.

Results

Inter-rater reliability of SIDE showed excellent reproducibility (Cohen's κ statistic = 0.76). Criterion-related validity was very high between SIDE levels and BBS scores (Spearman rank-correlation coefficient = 0.93; p < 0.01).

Conclusion

SIDE can be used to efficiently and accurately classify balance control ability across individuals and has remarkable concurrent validity in balance evaluation compared to BBS.

Zitieren

APA

Teranishi, T., Kondo, I., Sonoda, S., Kagaya, H., Wada, Y., Miyasaka, H., Tanino, G., Narita, W., Sakurai, H., Okada, M., & Saitoh, E. (2010). A discriminative measure for static postural control ability to prevent in-hospital falls: Reliability and validity of the Standing Test for Imbalance and Disequilibrium (SIDE). Japanese Journal of Comprehensive Rehabilitation Science. https://doi.org/10.11336/jjcrs.1.11

Vancouver

Teranishi T, Kondo I, Sonoda S, Kagaya H, Wada Y, Miyasaka H, et al. A discriminative measure for static postural control ability to prevent in-hospital falls: Reliability and validity of the Standing Test for Imbalance and Disequilibrium (SIDE). Japanese Journal of Comprehensive Rehabilitation Science. 2010. doi:10.11336/jjcrs.1.11

BibTeX
@article{Teranishi2010,
  author = {Teranishi, Toshio and Kondo, Izumi and Sonoda, Shigeru and Kagaya, Hitoshi and Wada, Yosuke and Miyasaka, Hiroyuki and Tanino, Genichi and Narita, Wataru and Sakurai, Hiroaki and Okada, Makoto and Saitoh, Eiichi},
  title = {A discriminative measure for static postural control ability to prevent in-hospital falls: Reliability and validity of the Standing Test for Imbalance and Disequilibrium (SIDE)},
  journal = {Japanese Journal of Comprehensive Rehabilitation Science},
  year = {2010},
  doi = {10.11336/jjcrs.1.11}
}
Kostenlos starten →