IS-Pro-based pathogen detection in explanted heart valves of suspected endocarditis patients
Microbiology Spectrum · 07.04.2026 · 14 (4)
DOI: 10.1128/spectrum.03984-25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microbiology Spectrum, erschienen am 07.04.2026. Verfasst von Patricia Bartsch und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Heart Valves, Endocarditis, Bacteria, Molecular Diagnostic Techniques. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für. Forschung, Technologie und Raumfahrt, InBiome.
Abstract (Originalsprache)
Accurate pathogen identification in infective endocarditis (IE) is limited, particularly in culture-negative cases. This study evaluated the performance of the Molecular Culture ID (MC-ID) assay in heart valve specimens from patients with suspected IE. Fifty-seven valve specimens from patients with suspected IE were analyzed using conventional culture, 16S/18S rDNA sequencing (SepsiTest, Molzym, Germany), the Biofire Joint Infection Panel (BJP; bioMérieux, Marcy l'Étoile, France), and MC-ID, with previously reported results as comparators. Twelve specimens (21.1%) were culture-positive, and 45 (78.9%) were culture-negative. MC-ID showed 83.3% positive agreement and 44.4% negative agreement with culture, achieving species-level concordance in 8/12 cases. Three culture-positive/MC-ID-negative results reflected organisms outside the assay’s detection range or limited taxonomic resolution. MC-ID detected pathogens in 25/45 (55.5%) culture-negative specimens; 21 were corroborated by PCR and/or BJP. Discrepancies largely reflected polymicrobial infections or taxonomic resolution limits. MC-ID identified pathogens in four PCR-/BJP-negative specimens, of which three likely were of clinical significance. MC-ID was negative in two culture-negative, PCR-/BJP-positive specimens. MC-ID can improve pathogen detection in both culture-positive and culture-negative IE, complementing conventional and molecular diagnostics and providing a comprehensive microbiological assessment in suspected IE cases. IMPORTANCE Infective endocarditis (IE) remains difficult to diagnose, especially when blood and tissue cultures fail to identify a pathogen. Accurate organism detection is essential for guiding targeted therapy and reducing reliance on broad-spectrum antibiotics. This study shows that the Molecular Culture ID (MC-ID) assay markedly improves diagnostic yield in culture-negative valve specimens, frequently identifying pathogens missed by conventional and molecular tests. MC-ID also clarifies cases complicated by polymicrobial infection or limited taxonomic resolution, providing species-level or clinically actionable identification in many instances. By complementing existing diagnostic methods and expanding detection beyond their constraints, MC-ID offers a more comprehensive microbiological assessment of suspected endocarditis. Its integration into diagnostic workflows has the potential to enhance clinical decision-making and improve management of this high-risk condition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Institute of Legal Medicine, Center for Diagnostics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
ORCID-Profile: Patricia Bartsch, Holger Rohde, Benjamin Berinson
Förderung
- Bundesministerium für. Forschung, Technologie und Raumfahrt
- InBiome
Zitieren
APA
Bartsch, P., Krebs, O., Augustin, C., Aepfelbacher, M., Rohde, H., & Berinson, B. (2026). IS-Pro-based pathogen detection in explanted heart valves of suspected endocarditis patients. Microbiology Spectrum, 14(4). https://doi.org/10.1128/spectrum.03984-25
Vancouver
Bartsch P, Krebs O, Augustin C, Aepfelbacher M, Rohde H, Berinson B. IS-Pro-based pathogen detection in explanted heart valves of suspected endocarditis patients. Microbiology Spectrum. 2026;14(4). doi:10.1128/spectrum.03984-25
BibTeX
@article{Bartsch2026,
author = {Bartsch, Patricia and Krebs, Oliver and Augustin, Christa and Aepfelbacher, Martin and Rohde, Holger and Berinson, Benjamin},
title = {IS-Pro-based pathogen detection in explanted heart valves of suspected endocarditis patients},
journal = {Microbiology Spectrum},
year = {2026},
volume = {14},
number = {4},
doi = {10.1128/spectrum.03984-25}
}
EUVIMED