EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization of the STARlet workflow for semi-automatic SARS-CoV-2 screening of swabs and deep respiratory materials using the RealAccurate Quadruplex SARS-CoV-2 PCR kit and Allplex SARS-CoV-2 PCR kit

Jacky Flipse iD, Angelino T Tromp, Danique Thijssen, Nicole van Xanten-Jans-Beken, Roy Pauwelsen, Harmen J van der Veer, Juliëtte M Schlaghecke, Caroline M A Swanink

Microbiology Spectrum · 2024

DOI: 10.1128/spectrum.03296-23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microbiology Spectrum, 2024. Verfasst von Jacky Flipse und 7 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Medical Microbiology and Immunology, Rijnstate Hospital, Velp, the Netherlands. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic triggered the implementation of large-scale screenings in the health care and in the general population. Consequently, medical laboratories have to apply lean laboratory management to design workflows that are able to process large batches within short turnaround times while maintaining flexibility to use different SARS-CoV-2 reverse transcription polymerase chain reactions (RT-PCRs) and to be able to process a variety of clinical samples. We validated two SARS-CoV-2 PCR assays on the STARlet workflow: Allplex SARS-CoV-2 PCR kit and RealAccurate Quadruplex SARS-CoV-2 PCR kit. Furthermore, we optimized and validated the STARlet workflow for semi-automatic screening for SARS-CoV-2 in upper respiratory swabs and deep respiratory materials (sputa, bronchoalveolar lavage, and aspirate). Strikingly, guanidine-containing lysis buffers allow for easy processing and can enhance sensitivity of SARS-COV-2 screening since sampling in these buffers may preserve viral transcripts as evident by the higher copy numbers of the SARS-CoV-2 N gene. Moreover, using the principles of lean laboratory management, several bottlenecks that are typical for medical laboratories were addressed. We show that lean laboratory management resulted in significant reduction of the turnaround times of the SARS-CoV-2 PCR in our laboratory. This report thus describes a useful framework for laboratories to implement similar semi-automated workflows. IMPORTANCE The SARS-CoV-2 pandemic triggered the implementation of large-scale screenings in the health care and in the general population. Consequently, medical laboratories had to adapt and evolve workflows that are able to process large batches within short turnaround times while maintaining flexibility to use different assays and to be able to process a variety of clinical samples. We describe how the need for increased outputs and greater flexibility was addressed with respect to clinical samples and assays (Allplex SARS-CoV-2 PCR and RealAccurate Quadruplex SARS-CoV-2 PCR). Strikingly, we found that upper respiratory swabs collected in guanidine-containing lysis buffers both improved the ease of processing as well as enhanced the sensitivity of the SARS-CoV-2 screening. This report thus describes a useful framework for laboratories to implement and optimize similar semi-automated workflows.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2COVID-19HumansWorkflowSensitivity and SpecificityGuanidinesPolymerase Chain ReactionCOVID-19 Testing

Stichwörter der Autor:innen

SARS-CoV-2laboratorium automationlean managementmolecular diagnosticsturnaround timevalidation

Substanzen

Guanidines

Autor:innen und Institutionen

  • Laboratory for Medical Microbiology and Immunology, Rijnstate Hospital, Velp, the Netherlands.
  • Laboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
  • Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, the Netherlands.
  • Research Group Applied Natural Sciences, Fontys University of Applied Sciences, Eindhoven, the Netherlands.

ORCID-Profile: Jacky Flipse

Zitieren

APA

Flipse, J., Tromp, A. T., Thijssen, D., van Xanten-Jans-Beken, N., Pauwelsen, R., van der Veer, H. J., Schlaghecke, J. M., & Swanink, C. M. A. (2024). Optimization of the STARlet workflow for semi-automatic SARS-CoV-2 screening of swabs and deep respiratory materials using the RealAccurate Quadruplex SARS-CoV-2 PCR kit and Allplex SARS-CoV-2 PCR kit. Microbiology Spectrum. https://doi.org/10.1128/spectrum.03296-23

Vancouver

Flipse J, Tromp AT, Thijssen D, van Xanten-Jans-Beken N, Pauwelsen R, van der Veer HJ, et al. Optimization of the STARlet workflow for semi-automatic SARS-CoV-2 screening of swabs and deep respiratory materials using the RealAccurate Quadruplex SARS-CoV-2 PCR kit and Allplex SARS-CoV-2 PCR kit. Microbiology Spectrum. 2024. doi:10.1128/spectrum.03296-23

BibTeX
@article{Flipse2024,
  author = {Flipse, Jacky and Tromp, Angelino T and Thijssen, Danique and van Xanten-Jans-Beken, Nicole and Pauwelsen, Roy and van der Veer, Harmen J and Schlaghecke, Juliëtte M and Swanink, Caroline M A},
  title = {Optimization of the STARlet workflow for semi-automatic SARS-CoV-2 screening of swabs and deep respiratory materials using the RealAccurate Quadruplex SARS-CoV-2 PCR kit and Allplex SARS-CoV-2 PCR kit},
  journal = {Microbiology Spectrum},
  year = {2024},
  doi = {10.1128/spectrum.03296-23}
}
Kostenlos starten →