Assessment of the clinical and analytical performance of three Seegene Allplex SARS-CoV-2 assays within the VALCOR framework

Pui Yan Jenny Chung iD, Sharonjit K Dhillon, Cindy Simoens, Lize Cuypers, Lies Laenen, Jesper Bonde, Philippe Corbisier, Gerhard Buttinger, Clementina E Cocuzza iD, Steven Van Gucht, Marc Van Ranst, Marc Arbyn iD

Microbiology Spectrum · 2024

DOI: 10.1128/spectrum.02397-23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microbiology Spectrum, 2024. Verfasst von Pui Yan Jenny Chung und 11 weiteren Autor:innen. Beteiligte Einrichtung: Unit of Cancer Epidemiology, Belgian Cancer Centre, Sciensano, Brussels, Belgium. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Belgische Federale Overheidsdiensten (Belgian Federal Government).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The coronavirus disease 2019 (COVID-19) pandemic demonstrated the need for accurate diagnostic testing for the early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although the pandemic has ended, accurate assays are still needed to monitor viral spread at national levels and beyond through population and wastewater surveillance. To enhance early detection, SARS-CoV-2 assays should have high diagnostic accuracy and should be validated to assure accurate results. Three distinct SARS-CoV-2 assays were evaluated with clinical samples using the VALCOR (VALidation of SARS-CORona Virus-2 assays) framework, with the TaqPath COVID-19 assay (ThermoFisher Scientific, USA) as a comparator. We evaluated clinical sensitivity, specificity, limit of detection (LOD), and overall concordance between comparator and three index Allplex SARS-CoV-2 assays (Seegene, South Korea): Allplex-SC2, Allplex-SC2Fast (Fast PCR), and Allplex-SC2FabR (SARS-CoV-2/FluA/FluB/respiratory syncytial virus). Analytical performance and LOD of index assays were assessed using a dilution series of three synthetic SARS-CoV-2 sequence reference materials (RMs). Ninety SARS-CoV-2 positives and 90 SARS-CoV-2 negatives were tested. All Allplex assays had 100.0% sensitivity (95%CI = 95.9%–100.0%). Allplex-SC2 and Allplex-SC2Fast assays had 97.8% specificity (95%CI = 92.3%–99.7%) and 98.9% overall concordance [ κ = 0.978 (95%CI = 0.947–1.000)]. Allplex-SC2FabR assay showed 100.0% specificity (95%CI = 95.9%–100.0%) and 100.0% overall concordance [ κ = 1.000 (95%CI = 1.000–1.000)]. LOD assessment of index assays revealed detection down to 2.61 × 10 2 copies/mL in clinical samples, while the analytical LOD was 9.00 × 10 2 copies/mL. In conclusion, the evaluation of the three Seegene Allplex SARS-CoV-2 assays showed high sensitivity and specificity and an overall good assay concordance with the comparator. The assays showed low analytical LOD using RM and even a slightly lower LOD in clinical samples. Non-overlapping target gene sequences between SARS-CoV-2 assays and RMs emphasize the need for aligning targeted sequences of diagnostic assays and RMs. IMPORTANCE The coronavirus disease 2019 pandemic has a significant impact on global public health, economies, and societies. As shown through the first phases of the pandemic, accurate and timely diagnosis is crucial for disease control, prevention, and monitoring. Though the pandemic phase of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has concluded, diagnostic assays remain in demand to monitor SARS-CoV-2 at the individual patient level, regionally, and nationally, as well as to remain an infectious disease preparedness instrument to monitor any new SARS-CoV-2 dissemination across borders using population and wastewater surveillance. The anticipation by WHO and central health care policy entities such as the Center for Disease Control, EMA, and multiple national health authorities is that SARS-CoV-2 will reside as an endemic respiratory disease for years to come. The key strategic consideration is hence shifting from combating a pandemic situation with a high number of patients to instead allowing precise diagnostics of suspected patients with the intention of correct management in a low-prevalence setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2COVID-19HumansWastewaterSensitivity and SpecificityWastewater-Based Epidemiological Monitoring

Stichwörter der Autor:innen

AllplexCOVID-19RT-PCRSARS-CoV-2SeegeneVALCORdiagnostics test accuracyquality controlreference materialstandardtest validation

Substanzen

Wastewater

Autor:innen und Institutionen

  • Unit of Cancer Epidemiology, Belgian Cancer Centre, Sciensano, Brussels, Belgium.
  • Department of Laboratory Medicine, National Reference Centre for Respiratory Pathogens, University Hospitals Leuven, Leuven, Belgium.
  • Laboratory of Clinical Microbiology, Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium.
  • Molecular Pathology Laboratory, Department of Pathology, AHH-Hvidovre Hospital, Copenhagen University Hospital, Copenhagen, Denmark.
  • Joint Research Centre (JRC), European Commission, Geel, Belgium.
  • Laboratory of Clinical Microbiology and Virology, Department of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy.

ORCID-Profile: Pui Yan Jenny Chung, Clementina E Cocuzza, Marc Arbyn

Förderung

  • Belgische Federale Overheidsdiensten (Belgian Federal Government)

Zitieren

APA

Chung, P. Y. J., Dhillon, S. K., Simoens, C., Cuypers, L., Laenen, L., Bonde, J., Corbisier, P., Buttinger, G., Cocuzza, C. E., Van Gucht, S., Van Ranst, M., & Arbyn, M. (2024). Assessment of the clinical and analytical performance of three Seegene Allplex SARS-CoV-2 assays within the VALCOR framework. Microbiology Spectrum. https://doi.org/10.1128/spectrum.02397-23

Vancouver

Chung PYJ, Dhillon SK, Simoens C, Cuypers L, Laenen L, Bonde J, et al. Assessment of the clinical and analytical performance of three Seegene Allplex SARS-CoV-2 assays within the VALCOR framework. Microbiology Spectrum. 2024. doi:10.1128/spectrum.02397-23

BibTeX
@article{Chung2024,
  author = {Chung, Pui Yan Jenny and Dhillon, Sharonjit K and Simoens, Cindy and Cuypers, Lize and Laenen, Lies and Bonde, Jesper and Corbisier, Philippe and Buttinger, Gerhard and Cocuzza, Clementina E and Van Gucht, Steven and Van Ranst, Marc and Arbyn, Marc},
  title = {Assessment of the clinical and analytical performance of three Seegene Allplex SARS-CoV-2 assays within the VALCOR framework},
  journal = {Microbiology Spectrum},
  year = {2024},
  doi = {10.1128/spectrum.02397-23}
}
Kostenlos starten →