Exploring the causes of variability in quality of oropharyngeal swab sampling for SARS-CoV-2 nucleic acid testing and proposed improvement measures: a multicenter, double-blind study
Microbiology Spectrum · 2024
DOI: 10.1128/spectrum.01567-24 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Microbiology Spectrum, 2024. Verfasst von Jie Zhu und 21 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Clinical Virology, Department of Infectious Diseases, The Second Affiliated Hospital of Anhui Medical University, Hefei, China. Hauptthemen laut MEDLINE: Specimen Handling, SARS-CoV-2, Oropharynx, COVID-19. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Although coronavirus disease 2019 (COVID-19) has not been considered a public health emergency of international concern since last year, intermittent regional impacts still persist, and accurate testing remains crucial. Ribonuclease P protein subunit P30 ( RPP30 ) RNA, known for its broad and stable expression in tissue cells, was used to evaluate samples from 10 hospitals with over 3,000 negative nucleic acid tests. The results revealed that the overall pass rate for the collected samples was consistently low and exhibited significant heterogeneity. After reassessing the evaluative effectiveness of RPP30 RNA Ct values from the samples of 132 positive individuals under quarantine observation, it was used to identify factors affecting sampling quality. These factors included different stages ranging from sample collection to PCR processing, various characteristics of both samplers and individuals being sampled, as well as sampling season and location. The results indicated that post-sampling handling had minimal impact, winter and fever clinic samples showed higher quality, whereas children’s samples had lower quality. The key finding was that the characteristics of samplers were closely related to sampling quality, emphasizing the role of subjectivity. Quality control warnings led to substantial improvements, confirming this finding. Consequently, although there are various factors during the testing process, the most critical aspect is to improve, supervise, and maintain standardized practices among sampling staff. IMPORTANCE This study further confirmed the reliability of internal references (IRs) in assessing sample quality, and utilized a large sample IR data to comprehensively and multidimensionally identify significant interference factors in nucleic acid test results. By further reminding and intervening in the subjective practices of specimen collectors, good results could be achieved.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Clinical Virology, Department of Infectious Diseases, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
- Department of Clinical Microbiology and Infection Control, The University of Hong Kong-Shenzhen Hospital, Shenzhen, China.
- Department of Infectious Diseases, The Third Affiliated Hospital of Anhui Medical University, The First People's Hospital of Hefei, Hefei, China.
- Department of Laboratory Medicine, Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- Division of Liver Disease, The Second People's Hospital of Fuyang City, Fuyang, China.
- Department of Clinical Laboratory, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
ORCID-Profile: Fanfan Xing, Jianbo Xia, Zhenhua Zhang
Zitieren
APA
Zhu, J., Xing, F., Li, Y., Wu, C., Li, S., Wang, Q., Huang, J., Zhang, Y., Zheng, X., Liu, Z., Rao, J., Hong, R., Tian, S., Xiong, S., Tan, L., Chen, X., Li, Y., He, W., Hong, X., …, & Zhang, Z. (2024). Exploring the causes of variability in quality of oropharyngeal swab sampling for SARS-CoV-2 nucleic acid testing and proposed improvement measures: a multicenter, double-blind study. Microbiology Spectrum. https://doi.org/10.1128/spectrum.01567-24
Vancouver
Zhu J, Xing F, Li Y, Wu C, Li S, Wang Q, et al. Exploring the causes of variability in quality of oropharyngeal swab sampling for SARS-CoV-2 nucleic acid testing and proposed improvement measures: a multicenter, double-blind study. Microbiology Spectrum. 2024. doi:10.1128/spectrum.01567-24
BibTeX
@article{Zhu2024,
author = {Zhu, Jie and Xing, Fanfan and Li, Yunzhu and Wu, Chunchen and Li, Shasha and Wang, Qin and Huang, Jinyue and Zhang, Yafei and Zheng, Xiaowei and Liu, Zhenjun and Rao, Jianguo and Hong, Rui and Tian, Shuilin and Xiong, Shuangyun and Tan, Lin and Chen, Xinlei and Li, Yanwu and He, Wei and Hong, Xiaodan and Xia, Jianbo and Zhou, Qiang and Zhang, Zhenhua},