EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Evaluation of the PA-100 AST system (Sysmex) for point-of-care analysis of bacteriuria and antibiotic susceptibility testing in dogs and cats

Sina Selent, Roswitha Dorsch iD, Georg Wolf iD, Karin Weber iD

Microbiology Spectrum · 2026

DOI: 10.1128/spectrum.00811-26 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Microbiology Spectrum, 2026. Verfasst von Sina Selent und 3 weiteren Autor:innen. Beteiligte Einrichtung: Small Animal Clinic, Centre for Clinical Veterinary Medicine, LMU Munich, Munich, Germany. Hauptthemen laut MEDLINE: Bacteriuria, Cat Diseases, Anti-Bacterial Agents, Dog Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: LMU Munich, Veterinary Faculty.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bacterial presence in urine (bacteriuria) is frequently observed in dogs and cats and may be associated with urinary tract infection (UTI), depending on the clinical context. However, no in-house test for the rapid detection of bacteriuria and subsequent antibiotic susceptibility tests (AST) is yet available. The Sysmex PA-100 AST System (PA-100) is a point-of-care (POC) analyzer using nanofluidic cartridges designed for the detection of bacteria and performance of AST directly from voided urine in female patients with cystitis symptoms. In this study, we tested the suitability of the PA-100 to detect UTIs and perform AST on veterinary samples. In total, 363 urine samples from dogs ( n = 163) and cats ( n = 200) collected via cystocentesis, catheter, endoscopy, or punctation of a ureteral bypass system were analyzed. The results were compared to routine microbiologic culture and AST. Using the manufacturer’s thresholds for bacteriuria, we observed a sensitivity of 87.1% (95% confidence interval [CI] 70.2–96.4), specificity of 81.7% (95% CI 73.6–88.1), positive predictive value (PPV) of 55.1% (CI 40.2–69.3), and negative predictive value (NPV) of 96.1% (95% CI 90.3–99.0) for UTIs of cats. For dogs, we observed a sensitivity of 87.1% (95% CI 70.2–96.4), specificity of 87.7% (95% CI 78.5–93.9), PPV of 73.0% (95% CI 55.9–86.2), and NPV of 94.7% (95% CI 86.9–98.5). The AST results of the PA-100 were concordant with the AST on plates in 90% of samples. The device has potential as a POC analyzer in the veterinary field, but a high proportion of false-positive bacteriuria results occurred. About 12% of samples yielded no results due to technical errors. Adjustments to the antibiotics used in the cartridges are required for veterinary medicine. IMPORTANCE Currently available point-of-care (POC) tests for the detection of bacteriuria in cats and dogs show several limitations, and antimicrobial susceptibility testing (AST) is not provided by most of these tests. These POC tests generally necessitate incubation for more than 16 h. The Sysmex PA-100 AST System (PA-100), which is designed as a POC device to detect bacteriuria and perform AST-testing within 45 min in urine samples of female patients suffering from cystitis, was recently tested for the first time in a clinical setting in human medicine. Since timely results to detect bacteriuria and to guide antibiotic use are just as important in companion animals as they are in humans, this study aimed to evaluate the applicability of the PA-100 for veterinary use, testing urine samples from dogs and cats with clinical signs of cystitis. This technology may support faster urinalysis in veterinary patients. However, its current applicability in veterinary diagnostics is limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BacteriuriaCat DiseasesAnti-Bacterial AgentsDog DiseasesPoint-of-Care SystemsBacteriaUrinary Tract InfectionsAnimalsCatsDogsFemaleMicrobial Sensitivity TestsSensitivity and SpecificityPoint-of-Care TestingRapid Diagnostic Tests

Stichwörter der Autor:innen

antibiotic stewardshipcaninediagnosticfelinenanofluidicspoint-of-care

Substanzen

Anti-Bacterial Agents

Autor:innen und Institutionen

  • Small Animal Clinic, Centre for Clinical Veterinary Medicine, LMU Munich, Munich, Germany.
  • Department of Bacteriology, Faculty of Veterinary Medicine, Institute of Infectious Diseases and Zoonoses, LMU Munich, Munich, Germany.

ORCID-Profile: Roswitha Dorsch, Georg Wolf, Karin Weber

Förderung

  • LMU Munich, Veterinary Faculty

Zitieren

APA

Selent, S., Dorsch, R., Wolf, G., & Weber, K. (2026). Evaluation of the PA-100 AST system (Sysmex) for point-of-care analysis of bacteriuria and antibiotic susceptibility testing in dogs and cats. Microbiology Spectrum. https://doi.org/10.1128/spectrum.00811-26

Vancouver

Selent S, Dorsch R, Wolf G, Weber K. Evaluation of the PA-100 AST system (Sysmex) for point-of-care analysis of bacteriuria and antibiotic susceptibility testing in dogs and cats. Microbiology Spectrum. 2026. doi:10.1128/spectrum.00811-26

BibTeX
@article{Selent2026,
  author = {Selent, Sina and Dorsch, Roswitha and Wolf, Georg and Weber, Karin},
  title = {Evaluation of the PA-100 AST system (Sysmex) for point-of-care analysis of bacteriuria and antibiotic susceptibility testing in dogs and cats},
  journal = {Microbiology Spectrum},
  year = {2026},
  doi = {10.1128/spectrum.00811-26}
}
Kostenlos starten →