Misidentification and misreporting of antibiotic resistance in Kluyvera bacteremia by blood culture molecular identification panels
Microbiology Spectrum · 2024
DOI: 10.1128/spectrum.00542-24 ↗Kurz gefasst
Fallbericht in der Zeitschrift Microbiology Spectrum, 2024. Verfasst von Darrick Vatterrodt und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Microbiology, MultiCare Health System, Tacoma, Washington, USA. Hauptthemen laut MEDLINE: Anti-Bacterial Agents, Bacteremia, beta-Lactamases, Blood Culture. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The use of molecular identification panels has advanced the diagnosis for blood stream infections with fast turnaround time and high accuracy. Yet, this technology cannot completely replace conventional blood culture and standardized antibiotic susceptibility testing (AST) given its limitations and occasional false results. Here we present two cases of bacteremia caused by Kluyvera . Its identification and antibiotic resistance were at least partially mispresented by blood culture molecular identification panels on ePlex, Verigene, and Biofire. The detection of CTX-M resistance marker did not align with the susceptibility to the third generation cephalosporins among a wide range of antibiotics for this organism. Conventional extended-spectrum beta-lactamase (ESBL) testing was used to confirm the absence of ESBL. Caution should be taken when managing cases with CTX-M or ESBL detection in blood culture caused by uncommon pathogens. Conventional culture with microbial identification and standardized AST should continue to be the gold standard for routine patient care. IMPORTANCE This is the first report that highlights the limitations of blood culture molecular identification panels on identifying Kluyvera and its associated antibiotic resistance patterns. Both the false identification and overreporting of antibiotic resistance could mislead the treatment for bacteremia caused by this pathogen. Patient isolation could have been avoided due to the lack of extended-spectrum beta-lactamase (ESBL) activity of the organism. This report emphasizes the importance of confirming rapid identification and antibiotic resistance by molecular technologies with standardized methods. It also provides insight into the development of new diagnostic panels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Microbiology, MultiCare Health System, Tacoma, Washington, USA.
- Department of Microbiology, Veterans Administration Puget Sound Health Care System, Seattle, Washington, USA.
ORCID-Profile: Janelle Lee, Siu-Kei Chow
Zitieren
APA
Vatterrodt, D., Lee, J., Ho, D., Stevig, C., & Chow, S. K. (2024). Misidentification and misreporting of antibiotic resistance in Kluyvera bacteremia by blood culture molecular identification panels. Microbiology Spectrum. https://doi.org/10.1128/spectrum.00542-24
Vancouver
Vatterrodt D, Lee J, Ho D, Stevig C, Chow SK. Misidentification and misreporting of antibiotic resistance in Kluyvera bacteremia by blood culture molecular identification panels. Microbiology Spectrum. 2024. doi:10.1128/spectrum.00542-24
BibTeX
@article{Vatterrodt2024,
author = {Vatterrodt, Darrick and Lee, Janelle and Ho, Dooil and Stevig, Craig and Chow, Siu-Kei},
title = {Misidentification and misreporting of antibiotic resistance in Kluyvera bacteremia by blood culture molecular identification panels},
journal = {Microbiology Spectrum},
year = {2024},
doi = {10.1128/spectrum.00542-24}
}
EUVIMED