Highly sensitive extraction-free saliva-based molecular assay for rapid diagnosis of SARS-CoV-2
Journal of Clinical Microbiology · 12.06.2024 · 62 (6)
DOI: 10.1128/jcm.00600-24 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Microbiology, erschienen am 12.06.2024. Verfasst von Michael Margulis und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering, The Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel. Hauptthemen laut MEDLINE: Saliva, COVID-19, SARS-CoV-2, Sensitivity and Specificity. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Israel Ministry of science and technology.
Abstract (Originalsprache)
The COVID-19 pandemic highlighted the necessity of fast, sensitive, and efficient methods to test large populations for respiratory viruses. The “gold standard” molecular assays for detecting respiratory viruses, such as quantitative polymerase chain reaction (qPCR) and reverse transcription qPCR (RT-qPCR), rely on invasive swab samples and require time-consuming and labor-intensive extraction processes. Moreover, the turnaround time for RT-qPCR-based assays is too lengthy for rapid screening. Extraction-free saliva-based methods provide a non-invasive sampling process with a fast turnaround time and are suitable for high-throughput applications. However, when used with a standard RT-qPCR system, the absence of extraction significantly reduces the assays’ sensitivity. Here, using a novel optical modulation biosensing (OMB) platform, we developed a rapid and highly sensitive extraction-free saliva-based molecular assay. We blindly tested 364 paired nasopharyngeal swabs and saliva samples from suspected SARS-CoV-2 cases in Israel. Compared with the gold standard swab-based RT-qPCR assay, the sensitivity of the extraction-free saliva-based OMB assay is 90.7%, much higher than the sensitivity of extraction-free saliva-based RT-qPCR assay (77.8%) with similar specificity (95.3% and 97.6%, respectively). Moreover, out of 12 samples identified by the OMB-based assay as positive, 8 samples were collected from hospitalized patients in a COVID-19 ward and were verified to be SARS-CoV-2-positive upon admission, indicating that the actual clinical sensitivity and specificity of the OMB assay are higher. Considering its user-friendly saliva-based protocol, short and cost-effective extraction-free process, and high clinical accuracy, the OMB-based molecular assay is very suitable for high-throughput testing of large populations for respiratory viruses. IMPORTANCE Three years after the SARS-CoV-2 outbreak, there are no molecular tests that combine low-cost and straightforward sample preparation, effective sample handling, minimal reagent and disposable requirements, high sensitivity, and high throughput required for mass screening. Existing rapid molecular techniques typically sacrifice certain requirements to meet others. Yet, localized outbreaks of novel viral diseases happen daily in different parts of the world. In this context, respiratory diseases are of specific importance, as they are frequently airborne and highly contagious, with the potential for a rapid global spread. The widely accepted opinion is that another pandemic is just a question of time. To ensure that the containment efforts for the upcoming “disease X” are successful, introducing rapid, high-throughput, and highly sensitive diagnostic methods for detecting and identifying pathogens is critical. A few months into the pandemic, saliva was suggested as a diagnostic matrix for SARS-CoV-2 detection. The collection of saliva does not require swabs and is minimally invasive. In particular, extraction-free saliva-based assays require fewer reagents and disposables, and therefore are faster and cheaper, offering an appealing alternative for low-income countries. Unfortunately, current extraction-free saliva-based detection methods, such as direct RT-qPCR or isothermal amplification, have either low sensitivity or low throughput. Therefore, we believe that the presented highly sensitive ht-OMBi platform and the extraction-free saliva-based molecular assay can become an essential tool in the infectious disease monitoring toolbox .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Engineering, The Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel.
- Clinical Microbiology Laboratory, The Tzafon Medical Center, Poriya, Tiberias, Israel.
- Central Virology Laboratory, Israel Ministry of Health, Chaim Sheba Medical Centre, Ramat Gan, Israel.
- Department of Epidemiology and Preventive Medicine, School of Public Health, Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
- The Center for Geographic Medicine, Chaim Sheba Medical Center, Ramat Gan, Israel.
- The Azrieli Faculty of Medicine, Bar-Ilan University, Safed, Israel.
ORCID-Profile: Michael Margulis, Oran Erster, Asaf Biber, Avi Peretz, Amos Danielli
Förderung
- Israel Ministry of science and technology
Zitieren
APA
Margulis, M., Rohana, H., Erster, O., Mandelboim, M., Biber, A., Schwartz, E., Peretz, A., & Danielli, A. (2024). Highly sensitive extraction-free saliva-based molecular assay for rapid diagnosis of SARS-CoV-2. Journal of Clinical Microbiology, 62(6). https://doi.org/10.1128/jcm.00600-24
Vancouver
Margulis M, Rohana H, Erster O, Mandelboim M, Biber A, Schwartz E, et al. Highly sensitive extraction-free saliva-based molecular assay for rapid diagnosis of SARS-CoV-2. Journal of Clinical Microbiology. 2024;62(6). doi:10.1128/jcm.00600-24
BibTeX
@article{Margulis2024,
author = {Margulis, Michael and Rohana, Hanan and Erster, Oran and Mandelboim, Michal and Biber, Asaf and Schwartz, Eli and Peretz, Avi and Danielli, Amos},
title = {Highly sensitive extraction-free saliva-based molecular assay for rapid diagnosis of SARS-CoV-2},
journal = {Journal of Clinical Microbiology},
year = {2024},
volume = {62},
number = {6},
doi = {10.1128/jcm.00600-24}
}
EUVIMED