Rapid and sensitive detection of chikungunya virus using one-tube, reverse transcription, semi-nested multi-enzyme isothermal rapid amplification, and lateral flow dipstick assays
Journal of Clinical Microbiology · 11.09.2024 · 62 (9)
DOI: 10.1128/jcm.00383-24 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Clinical Microbiology, erschienen am 11.09.2024. Verfasst von Xinlin Wu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Life Science and Technology, Kunming University of Science and Technology, Kunming, Yunnan, China. Hauptthemen laut MEDLINE: Chikungunya virus, Sensitivity and Specificity, Chikungunya Fever, Nucleic Acid Amplification Techniques. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Yunnan Major Scientific and Technological Project, MOST | National Natural Science Foundation of China (NSFC), Youth Talent Program of Yunnan "Ten-thousand Talents Program.
Abstract (Originalsprache)
Chikungunya fever is an acute infectious disease caused by chikungunya virus (CHIKV), which is transmitted by Aedes mosquitoes. Simple, rapid, and sensitive detection of CHIKV is critical for its prevention and spread. To address this issue, we combined one-tube, reverse transcription semi-nested, multi-enzyme isothermal rapid amplification, and lateral flow dipstick strips assay to detect CHIKV RNA. The study used a 318-bp gene fragment of CHIKV NSP4 as the target of the assay. This method of amplification takes 30 min for two-step amplification at 39°C. The dilution of amplification products was added to the LFD strip with results visible to the naked eye after 10 min. The method has a sensitivity of 1 copy/μL for the detection of CHIKV RNA, which is 100-fold higher than the conventional reverse transcription-multi-enzyme isothermal rapid amplification and 10-fold higher than the reverse transcription quantitative PCR (RT-qPCR) method. In addition, the method demonstrated good specificity and a better detection rate (85.7%, 18 of 21) than RT-qPCR (80.9%, 17 of 21) in clinically confirmed patient plasma samples. Thus, the rapid CHIKV RNA assay developed in this study will be an important tool for the rapid and accurate screening of patients for chikungunya fever. IMPORTANCE This study presents a new one-tube, reverse transcription semi-nested, multi-enzyme isothermal rapid amplification assay combined with lateral flow dipstick strips for the detection of CHIKV. This technique significantly improves sensitivity and outperforms RT-qPCR for the detection of CHIKV, especially in samples with low viral loads. It is also significantly faster than conventional RT-qPCR and does not require special equipment or a standard PCR laboratory. The combination of the isothermal amplification technology developed in this study with point-of-care molecular testing offers the potential for rapid, on-site, low-cost molecular diagnosis of CHIKV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Life Science and Technology, Kunming University of Science and Technology, Kunming, Yunnan, China.
- Yunnan Kecan Biotechnology Co., Ltd, Kunming, Yunnan, China.
- Yunnan Provincial Key Laboratory of Public Health and Biosafety, Kunming Medical University, Kunming, Yunnan, China.
ORCID-Profile: Xueshan Xia, Yue Feng
Förderung
- Yunnan Major Scientific and Technological Project
- MOST | National Natural Science Foundation of China (NSFC)
- Youth Talent Program of Yunnan "Ten-thousand Talents Program
Zitieren
APA
Wu, X., Liu, G., Chang, Y., Zheng, M., Liu, L., Xia, X., & Feng, Y. (2024). Rapid and sensitive detection of chikungunya virus using one-tube, reverse transcription, semi-nested multi-enzyme isothermal rapid amplification, and lateral flow dipstick assays. Journal of Clinical Microbiology, 62(9). https://doi.org/10.1128/jcm.00383-24
Vancouver
Wu X, Liu G, Chang Y, Zheng M, Liu L, Xia X, et al. Rapid and sensitive detection of chikungunya virus using one-tube, reverse transcription, semi-nested multi-enzyme isothermal rapid amplification, and lateral flow dipstick assays. Journal of Clinical Microbiology. 2024;62(9). doi:10.1128/jcm.00383-24
BibTeX
@article{Wu2024,
author = {Wu, Xinlin and Liu, Gaowen and Chang, Yingchao and Zheng, Mengyuan and Liu, Li and Xia, Xueshan and Feng, Yue},
title = {Rapid and sensitive detection of chikungunya virus using one-tube, reverse transcription, semi-nested multi-enzyme isothermal rapid amplification, and lateral flow dipstick assays},
journal = {Journal of Clinical Microbiology},
year = {2024},
volume = {62},
number = {9},
doi = {10.1128/jcm.00383-24}
}
EUVIMED