Inflated Gamma Interferon Response with QuantiFERON-TB Gold Plus Using the Automated Liaison XL Analyzer: a Testing Algorithm To Mitigate False-Positive Results in Low-Incidence Settings
Journal of Clinical Microbiology · 20.06.2023 · 61 (6)
DOI: 10.1128/jcm.00295-23 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Microbiology, erschienen am 20.06.2023. Verfasst von Vladimir Buron und 1 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Microbiology Laboratory, Stanford Health Care, Stanford, California, USA. Hauptthemen laut MEDLINE: Latent Tuberculosis, Tuberculosis, Mycobacterium tuberculosis. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The Liaison XL chemiluminescence immunoassay (CLIA) analyzer allows total automation of gamma interferon (IFN-γ) measurement for the QuantiFERON-TB Gold Plus assay (QFT-Plus) that is used to diagnose Mycobacterium tuberculosis infection. To evaluate CLIA accuracy, plasma samples from 278 patients undergoing QFT-Plus testing were first tested with an enzyme-linked immunosorbent assay (ELISA; 150 negatives and 128 positives) and subsequently with the CLIA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Microbiology Laboratory, Stanford Health Care, Stanford, California, USA.
- Department of Pathology, Stanford University School of Medicine, Stanford, California, USA.
- Division of Infectious Diseases & Geographic Medicine, Stanford University School of Medicine, Stanford, California, USA.
ORCID-Profile: Niaz Banaei
Zitieren
APA
Buron, V., & Banaei, N. (2023). Inflated Gamma Interferon Response with QuantiFERON-TB Gold Plus Using the Automated Liaison XL Analyzer: a Testing Algorithm To Mitigate False-Positive Results in Low-Incidence Settings. Journal of Clinical Microbiology, 61(6). https://doi.org/10.1128/jcm.00295-23
Vancouver
Buron V, Banaei N. Inflated Gamma Interferon Response with QuantiFERON-TB Gold Plus Using the Automated Liaison XL Analyzer: a Testing Algorithm To Mitigate False-Positive Results in Low-Incidence Settings. Journal of Clinical Microbiology. 2023;61(6). doi:10.1128/jcm.00295-23
BibTeX
@article{Buron2023,
author = {Buron, Vladimir and Banaei, Niaz},
title = {Inflated Gamma Interferon Response with QuantiFERON-TB Gold Plus Using the Automated Liaison XL Analyzer: a Testing Algorithm To Mitigate False-Positive Results in Low-Incidence Settings},
journal = {Journal of Clinical Microbiology},
year = {2023},
volume = {61},
number = {6},
doi = {10.1128/jcm.00295-23}
}
EUVIMED