Beobachtungsstudie in der Zeitschrift Journal of Clinical Microbiology, erschienen am 12.08.2026. Verfasst von Bruno Luukinen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Fimlab Laboratoriot, Tampere, Finland. Hauptthemen laut MEDLINE: Clinical Laboratory Techniques, Influenza, Human, Molecular Diagnostic Techniques, Respiratory Syncytial Virus Infections. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tampereen Tuberkuloosisäätiö.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and accurate diagnostics of epidemic respiratory viruses are relevant for optimal care pathways. In this observational diagnostic accuracy study, the novel Cobas Liat assay (Roche Molecular Systems) was evaluated for the detection of SARS-CoV-2, influenza A and B, and respiratory syncytial virus (RSV) in the clinical setting of Tampere University Hospital, Tampere, Finland. In addition, the added value of the tetraplex assay instead of two partially overlapping triplex assays (influenza A/B and SARS-CoV-2 or RSV) was assessed in the context of adult and pediatric emergency department (AED, PED) point-of-care (PoC) testing environments. A total of 315 clinical nasopharyngeal swab samples were analyzed. Diagnostic accuracy was evaluated against a molecular diagnostic reference. The evaluated Cobas Liat assay had sensitivities and specificities of 100% and 98.5% for influenza A, 100% and 99.7% for influenza B, 100% and 98.2% for SARS-CoV-2, and 100% and 97.0% for RSV, respectively. Among the index and reference tests, the Cobas Liat assay demonstrated the highest analytical sensitivity for influenza A, SARS-CoV-2, and RSV. No cross-reactivity with off-panel microbes was observed. With respect to clinical applicability, implementation of the evaluated tetraplex test would decrease double testing with two triplex tests in PED, likely decreasing costs and hands-on work. In AED, tetraplex testing would likely significantly increase the diagnostic yield for RSV, only rarely covered by PoC testing in AED. The evaluated Cobas Liat assay had excellent clinical and analytical accuracy, being highly suitable for PoC use but also for laboratory-based testing of influenza viruses, SARS-CoV-2, and RSV. IMPORTANCE Until recently, rapid point-of-care diagnostics have been somewhat limited by triplex four-channel analysis technology, separating four of the most important epidemic respiratory viruses—influenza A, influenza B, respiratory syncytial virus, and SARS-CoV-2—into two individual triplex tests. The evaluated tetraplex respiratory viral assay combines the two partially overlapping tests into a single test, streamlining analysis in two-test settings and potentially reducing diagnostic gaps in one-test settings. To our knowledge, this is the first study to describe the diagnostic accuracy of the novel Cobas Liat SARS-CoV-2, influenza A/B, and respiratory syncytial virus (RSV) assay with additional considerations for analytical sensitivity and specificity, and clinical utility in adult and pediatric emergency department use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Clinical Laboratory TechniquesInfluenza, HumanMolecular Diagnostic TechniquesRespiratory Syncytial Virus InfectionsAdolescentAdultChildChild, PreschoolFemaleHumansInfantMaleCOVID-19COVID-19 TestingFinlandInfluenza A virusInfluenza B virusNasopharynxPandemicsPoint-of-Care SystemsPoint-of-Care TestingRapid Diagnostic TestsRespiratory Syncytial Virus, HumanRespiratory Syncytial Viruses

Stichwörter der Autor:innen

SARS-CoV-2influenzamolecular diagnosticspoint-of-carerespiratory infectionsrespiratory syncytial virus

Autor:innen und Institutionen

  • Fimlab Laboratoriot, Tampere, Finland.
  • Faculty of Medicine, University of Helsinki, Helsinki, Finland.
  • Faculty of Agriculture and Forestry, University of Helsinki, Helsinki, Finland.
  • Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.

ORCID-Profile: Bruno Luukinen, Mika Lång

Förderung

  • Tampereen Tuberkuloosisäätiö

Zitieren

APA

Luukinen, B., Lång, M., Peltola, M., Soinila, A., Jarvala, T., Seiskari, T., & Paloniemi, M. (2026). From triplex to tetraplex: evaluation of the diagnostic accuracy of the new Roche Cobas Liat SARS-CoV-2, influenza A/B & RSV assay. Journal of Clinical Microbiology, 64(8). https://doi.org/10.1128/jcm.00274-26

Vancouver

Luukinen B, Lång M, Peltola M, Soinila A, Jarvala T, Seiskari T, et al. From triplex to tetraplex: evaluation of the diagnostic accuracy of the new Roche Cobas Liat SARS-CoV-2, influenza A/B & RSV assay. Journal of Clinical Microbiology. 2026;64(8). doi:10.1128/jcm.00274-26

BibTeX
@article{Luukinen2026,
  author = {Luukinen, Bruno and Lång, Mika and Peltola, Maria and Soinila, Arttu and Jarvala, Tiina and Seiskari, Tapio and Paloniemi, Minna},
  title = {From triplex to tetraplex: evaluation of the diagnostic accuracy of the new Roche Cobas Liat SARS-CoV-2, influenza A/B & RSV assay},
  journal = {Journal of Clinical Microbiology},
  year = {2026},
  volume = {64},
  number = {8},
  doi = {10.1128/jcm.00274-26}
}
Kostenlos starten →