EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Enhancing blood culture volume with ultrathin-wall cannula devices

Grant Johnson, Valentin Parvu, Stephane Beauchamp, Mike Cuttler, Arek Zubrzycki, Lauren Cooper iD

Journal of Clinical Microbiology · 2025

DOI: 10.1128/jcm.00208-25 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Clinical Microbiology, 2025. Verfasst von Grant Johnson und 5 weiteren Autor:innen. Beteiligte Einrichtung: Lakeridge Health, Oshawa, Ontario, Canada. Hauptthemen laut MEDLINE: Blood Culture, Cannula, Specimen Handling. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Suboptimal blood volume collection negatively affects pathogen recovery and time to pathogen detection in clinical blood culture samples. This study evaluated the performance of the ultrathin-wall cannula device of the BD Vacutainer UltraTouch Push Button Blood Collection Set (UltraTouch; BD Life Sciences, Franklin Lakes, NJ) in increasing the blood volume collected compared to regular cannulas. In this retrospective study, the volume of blood collected in negative BD BACTEC Plus Aerobic/F Culture Vials prior to and following blind conversion to UltraTouch was measured from blood background metabolic activity signal acquired during the initial incubation period in the BD BACTEC FX instrument using a custom software application (patent pending). Differences in average fill volume between pre- and post-conversion were evaluated overall and by month. A separate logistic regression was also performed to model the relationship between monthly average blood volume increase (mL) and sample positivity rate. Prevalence rates for identified organisms were also assessed. The blood fill volume of 13,356 pre-conversion and 119,971 post-conversion bottles was compared. The average post-conversion fill volume was significantly higher than that of pre-conversion (7.56 mL [95% CI, 7.54–7.59] vs. 5.68 mL [95% CI, 5.62–5.74], respectively). This 1.88 mL increase in collected blood volume increased sample positivity from 7.0% to 7.7% ( P = 0.002; odds ratio [OR], 1.11; 95% CI, 1.04–1.19). This study demonstrated that using an ultrathin-wall cannula blood collection device can significantly increase blood culture volume and sample positivity, supporting improved identification of patients suffering from bloodstream infections. IMPORTANCE Substandard blood fill volume practices in clinical settings negatively affect pathogen recovery which, in turn, may impact patients’ care. Whereas professional education regarding the importance of adhering to clinical guidelines has been helpful in partly remediating the issue, the role of blood collection set technologies in optimizing blood culture volume has not been studied as thoroughly. Our study assessed the performance of the BD Vacutainer UltraTouch Push Button Blood Collection Set, which is designed with an ultrathin-wall cannula, to improve blood culture volume.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood CultureCannulaSpecimen HandlingHumansRetrospective Studies

Stichwörter der Autor:innen

BACTECUltraTouchblood cultureblood volumecannuladiagnostics

Autor:innen und Institutionen

  • Lakeridge Health, Oshawa, Ontario, Canada.
  • Becton, Dickinson, and Company, Diagnostic Solutions, Sparks, Maryland, USA.
  • Becton, Dickinson and Company, Life Sciences, Mississauga, Ontario, Canada.

ORCID-Profile: Lauren Cooper

Zitieren

APA

Johnson, G., Parvu, V., Beauchamp, S., Cuttler, M., Zubrzycki, A., & Cooper, L. (2025). Enhancing blood culture volume with ultrathin-wall cannula devices. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00208-25

Vancouver

Johnson G, Parvu V, Beauchamp S, Cuttler M, Zubrzycki A, Cooper L. Enhancing blood culture volume with ultrathin-wall cannula devices. Journal of Clinical Microbiology. 2025. doi:10.1128/jcm.00208-25

BibTeX
@article{Johnson2025,
  author = {Johnson, Grant and Parvu, Valentin and Beauchamp, Stephane and Cuttler, Mike and Zubrzycki, Arek and Cooper, Lauren},
  title = {Enhancing blood culture volume with ultrathin-wall cannula devices},
  journal = {Journal of Clinical Microbiology},
  year = {2025},
  doi = {10.1128/jcm.00208-25}
}
Kostenlos starten →