EUVIMEDEUVIMED entdecken
Open Access

Diagnostic accuracy of tongue swab testing on two automated tuberculosis diagnostic platforms, Cepheid Xpert MTB/RIF Ultra and Molbio Truenat MTB Ultima

Rachel C Wood, Angelique K Luabeya, Rane B Dragovich, Alaina M Olson, Katherine A Lochner, Kris M Weigel, Renée Codsi, Humphrey Mulenga, Margaretha de Vos iD, Mikashmi Kohli, Adam Penn-Nicholson iD, Mark Hatherill und 1 weitere

Journal of Clinical Microbiology · 2024

DOI: 10.1128/jcm.00019-24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Microbiology, 2024. Verfasst von Rachel C Wood und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, Washington, USA. Hauptthemen laut MEDLINE: Tuberculosis, Pulmonary, Mycobacterium tuberculosis, Tuberculosis. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, HHS | NIH | National Institute of Allergy and Infectious Diseases, Bill and Melinda Gates Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tongue dorsum swabbing is a potential alternative to sputum collection for tuberculosis (TB) testing. Previous studies showed that Cepheid Xpert MTB/RIF Ultra (Xpert Ultra) can detect Mycobacterium tuberculosis DNA on tongue swabs stored in buffer, with 72% sensitivity and 100% specificity relative to a sputum microbiological reference standard (sputum MRS). The present study evaluated a more convenient sample collection protocol (dry swab storage), combined with streamlined sample processing protocols, for evaluating two commercial TB diagnostic tests: Xpert Ultra and Molbio Truenat MTB Ultima (MTB Ultima). Copan FLOQSwabs were self-collected or collected by study workers from 321 participants in Western Cape, South Africa. All participants had symptoms suggestive of TB, and 245 of them had sputum MRS-confirmed TB (by sputum MGIT culture and/or Xpert Ultra). One tongue swab per participant was tested on Xpert Ultra, and another tongue swab was tested with MTB Ultima. Xpert Ultra was 75.5% sensitive and 100% specific relative to sputum MRS, similar to previous methods that used swabs stored in buffer. MTB Ultima was 71.6% sensitive and 96.9% specific relative to sputum MRS. When sample lysates that were false-negative or invalid by MTB Ultima were frozen, thawed, and re-tested, MTB Ultima sensitivity rose to 79.1%. Both tests were more sensitive with swabs from participants with higher sputum Xpert Ultra semi-quantitative results. Although additional development could improve diagnostic accuracy, these results further support tongue swabs as easy-to-collect samples for TB testing. IMPORTANCE Tongue dorsum swabbing is a promising alternative to sputum collection for tuberculosis (TB) testing. Our results lend further support for tongue swabs as exceptionally easy-to-collect samples for high-throughput TB testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tuberculosis, PulmonaryMycobacterium tuberculosisTuberculosisHumansSensitivity and SpecificitySouth AfricaSputum

Stichwörter der Autor:innen

non-invasivenon-sputum samplingoral swabtongue swabtuberculosis diagnosistuberculosis screening

Autor:innen und Institutionen

  • Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, Washington, USA.
  • South African Tuberculosis Vaccine Initiative, Institute of Infectious Disease & Molecular Medicine and Department of Pathology, University of Cape Town, Cape Town, South Africa.
  • FIND, Geneva, Switzerland.

ORCID-Profile: Margaretha de Vos, Adam Penn-Nicholson, Gerard A Cangelosi

Förderung

  • NIAID NIH HHS
  • HHS | NIH | National Institute of Allergy and Infectious Diseases
  • Bill and Melinda Gates Foundation
  • Australian Government
  • University of Washington DEOHS Top Scholar Award

Zitieren

APA

Wood, R. C., Luabeya, A. K., Dragovich, R. B., Olson, A. M., Lochner, K. A., Weigel, K. M., Codsi, R., Mulenga, H., de Vos, M., Kohli, M., Penn-Nicholson, A., Hatherill, M., & Cangelosi, G. A. (2024). Diagnostic accuracy of tongue swab testing on two automated tuberculosis diagnostic platforms, Cepheid Xpert MTB/RIF Ultra and Molbio Truenat MTB Ultima. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00019-24

Vancouver

Wood RC, Luabeya AK, Dragovich RB, Olson AM, Lochner KA, Weigel KM, et al. Diagnostic accuracy of tongue swab testing on two automated tuberculosis diagnostic platforms, Cepheid Xpert MTB/RIF Ultra and Molbio Truenat MTB Ultima. Journal of Clinical Microbiology. 2024. doi:10.1128/jcm.00019-24

BibTeX
@article{Wood2024,
  author = {Wood, Rachel C and Luabeya, Angelique K and Dragovich, Rane B and Olson, Alaina M and Lochner, Katherine A and Weigel, Kris M and Codsi, Renée and Mulenga, Humphrey and de Vos, Margaretha and Kohli, Mikashmi and Penn-Nicholson, Adam and Hatherill, Mark and Cangelosi, Gerard A},
  title = {Diagnostic accuracy of tongue swab testing on two automated tuberculosis diagnostic platforms, Cepheid Xpert MTB/RIF Ultra and Molbio Truenat MTB Ultima},
  journal = {Journal of Clinical Microbiology},
  year = {2024},
  doi = {10.1128/jcm.00019-24}
}
Kostenlos starten →