EUVIMEDEUVIMED entdecken
Open Access

On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems

Raymond M Hozalski iD, Xiaotian Zhao, Taegyu Kim iD, Timothy M LaPara iD

Applied and Environmental Microbiology · 2024

DOI: 10.1128/aem.01658-23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied and Environmental Microbiology, 2024. Verfasst von Raymond M Hozalski und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Drinking Water, Legionella pneumophila, Mycobacterium, Legionella. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Minnesota Environment and Natural Resources Trust Fund (ENRTF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we compared conventional vacuum filtration of small volumes through disc membranes (effective sample volumes for potable water: 0.3–1.0 L) with filtration of high volumes using ultrafiltration (UF) modules (effective sample volumes for potable water: 10.6–84.5 L) for collecting bacterial biomass from raw, finished, and tap water at seven drinking water systems. Total bacteria, Legionella spp., Legionella pneumophila , Mycobacterium spp., and Mycobacterium avium complex in these samples were enumerated using both conventional quantitative PCR (qPCR) and viability qPCR (using propidium monoazide). In addition, PCR-amplified gene fragments were sequenced for microbial community analysis. The frequency of detection (FOD) of Legionella spp. in finished and tap water samples was much greater using UF modules (83% and 77%, respectively) than disc filters (24% and 33%, respectively). The FODs for Mycobacterium spp. in raw, finished, and tap water samples were also consistently greater using UF modules than disc filters. Furthermore, the number of observed operational taxonomic units and diversity index values for finished and tap water samples were often substantially greater when using UF modules as compared to disc filters. Conventional and viability qPCR yielded similar results, suggesting that membrane-compromised cells represented a minor fraction of total bacterial biomass. In conclusion, our research demonstrates that large-volume filtration using UF modules improved the detection of opportunistic pathogens at the low concentrations typically found in public drinking water systems and that the majority of bacteria in these systems appear to be viable in spite of disinfection with free chlorine and/or chloramine. IMPORTANCE Opportunistic pathogens, such as Legionella pneumophila , are a growing public health concern. In this study, we compared sample collection and enumeration methods on raw, finished, and tap water at seven water systems throughout the State of Minnesota, USA. The results showed that on-site filtration of large water volumes (i.e., 500–1,000 L) using ultrafiltration membrane modules improved the frequency of detection of relatively rare organisms, including opportunistic pathogens, compared to the common approach of filtering about 1 L using disc membranes. Furthermore, results from viability quantitative PCR (qPCR) with propidium monoazide were similar to conventional qPCR, suggesting that membrane-compromised cells represent an insignificant fraction of microorganisms. Results from these ultrafiltration membrane modules should lead to a better understanding of the microbial ecology of drinking water distribution systems and their potential to inoculate premise plumbing systems with opportunistic pathogens where conditions are more favorable for their growth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drinking WaterLegionella pneumophilaMycobacteriumLegionellaAzidesPropidiumWater MicrobiologyWater Supply

Stichwörter der Autor:innen

Legionella pneumophilaLegionella spp.Mycobacterium avium complexnontuberculous mycobacteriapropidium monoazidequantitative PCRultrafiltration

Substanzen

Drinking Waterpropidium monoazidePropidiumAzides

Autor:innen und Institutionen

  • Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA.
  • Biotechnology Institute, University of Minnesota Twin Cities, St. Paul, Minnesota, USA.

ORCID-Profile: Raymond M Hozalski, Taegyu Kim, Timothy M LaPara

Förderung

  • Minnesota Environment and Natural Resources Trust Fund (ENRTF)

Zitieren

APA

Hozalski, R. M., Zhao, X., Kim, T., & LaPara, T. M. (2024). On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.01658-23

Vancouver

Hozalski RM, Zhao X, Kim T, LaPara TM. On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems. Applied and Environmental Microbiology. 2024. doi:10.1128/aem.01658-23

BibTeX
@article{Hozalski2024,
  author = {Hozalski, Raymond M and Zhao, Xiaotian and Kim, Taegyu and LaPara, Timothy M},
  title = {On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems},
  journal = {Applied and Environmental Microbiology},
  year = {2024},
  doi = {10.1128/aem.01658-23}
}
Kostenlos starten →