EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Water-soluble swab material for environmental sampling

Kevin K Crown iD, Timothy N Lambert iD, Maria Kelly iD, Nelson S Bell iD, Joshua Santarpia iD

Applied and Environmental Microbiology · 20.05.2026 · 92 (5)

DOI: 10.1128/aem.00030-26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied and Environmental Microbiology, erschienen am 20.05.2026. Verfasst von Kevin K Crown und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of WMD Threats & Aerosol Science, Sandia National Laboratories, Albuquerque, New Mexico, USA. Hauptthemen laut MEDLINE: Specimen Handling. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sandia National Laboratories (SNL).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biological threats represent a growing vulnerability to national security, affecting both military and civilian populations. Deliberate dissemination of chemical and biological (CB) agents can have immediate and significant impacts on public health and the economy, highlighting the need for faster and more efficient techniques to assess contamination and safely clear affected areas for public reentry following an accidental or intentional biological release. Current surface sampling procedures set forth by the Centers for Disease Control and Prevention (CDC) call for sampling swab materials that are not soluble in aqueous bacterial growth medium. These have been shown here to be inefficient, releasing less than 40% of the captured biological material into aqueous solution for detection. Since the CDC put these procedures in place, there has been no impetus for industry to develop sampling swabs that release 100% of the sample they capture from a non-porous surface. This project developed cost-effective, novel, biologically hospitable, adsorbent materials that dissolve in water, releasing 100% of the captured sample. These fibers maintain structural integrity during sampling, can be premoistened without premature dissolution, and rapidly dissolve in solution, facilitating efficient sample release. Forcespun PVA fibrous swabs demonstrated significantly higher spore capture and release efficiency compared to traditional materials, without inhibiting bacterial growth or spore germination. These swabs could significantly improve current sampling technologies and procedures via increased spore detection and analysis efficiency. Higher sampling efficiency could translate to fewer samples required for analysis and significantly less time to render an area safe for public reentry. Increased sampling efficiency would also provide faster impact data to decision makers and lead to improved consequence management. Prior to this study, water-soluble swabs suitable for this purpose have not yet been developed. IMPORTANCE Accurate environmental sampling is critical for detecting low‐level microbial contamination in both public health and biodefense settings. Our water‐soluble PVA swab material achieves up to 100% spore release from non-porous surfaces, more than double the recovery of traditional swabs, while being compatible with scalable, low‐cost fabrication methods. This new tool will enable more sensitive, faster, and more reliable surface monitoring across a wide range of environmental and diagnostic applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Specimen HandlingSpores, BacterialWaterPolyvinyl AlcoholSolubility

Stichwörter der Autor:innen

Bacillus thuringiensis sporesForcespinning technologybiological threat detectionbioterrorismclearance samplingcontamination assessmentcotton candy machine fiber productionenvironmental decontaminationenvironmental samplingfiber characterizationmicrofluidic integrationpolyvinyl alcohol (PVA) fibersspore recoverysurface sampling efficiencywater-soluble swabs

Substanzen

WaterPolyvinyl Alcohol

Autor:innen und Institutionen

  • Department of WMD Threats & Aerosol Science, Sandia National Laboratories, Albuquerque, New Mexico, USA.
  • Department of Photovoltaics and Materials Technology, Sandia National Laboratories, Albuquerque, New Mexico, USA.
  • Sandia National Laboratories, Center for Integrated Nanotechnologies, Albuquerque, New Mexico, USA.
  • Advanced Materials Laboratory, Sandia National Laboratories, Albuquerque, New Mexico, USA.
  • Global Center for Health Security and Department of Pathology, Microbiology and Immunology, University of Nebraska Medical Center, Omaha, Nebraska, USA.

ORCID-Profile: Kevin K Crown, Timothy N Lambert, Maria Kelly, Nelson S Bell, Joshua Santarpia

Förderung

  • Sandia National Laboratories (SNL)

Zitieren

APA

Crown, K. K., Lambert, T. N., Kelly, M., Bell, N. S., & Santarpia, J. (2026). Water-soluble swab material for environmental sampling. Applied and Environmental Microbiology, 92(5). https://doi.org/10.1128/aem.00030-26

Vancouver

Crown KK, Lambert TN, Kelly M, Bell NS, Santarpia J. Water-soluble swab material for environmental sampling. Applied and Environmental Microbiology. 2026;92(5). doi:10.1128/aem.00030-26

BibTeX
@article{Crown2026,
  author = {Crown, Kevin K and Lambert, Timothy N and Kelly, Maria and Bell, Nelson S and Santarpia, Joshua},
  title = {Water-soluble swab material for environmental sampling},
  journal = {Applied and Environmental Microbiology},
  year = {2026},
  volume = {92},
  number = {5},
  doi = {10.1128/aem.00030-26}
}
Kostenlos starten →