EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bacterial bioluminescence for the real time and in situ monitoring of endoscope disinfection using plasma activated water

Naomi Northage iD, Joshua A C Steven iD, Darren M Reynolds iD, Malcolm J Horsburgh iD, James L Walsh, Robin M S Thorn iD

Antimicrobial Agents and Chemotherapy · 2026

DOI: 10.1128/aac.01380-25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Antimicrobial Agents and Chemotherapy, 2026. Verfasst von Naomi Northage und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department for Gaseous Electronics, Jožef Stefan Institute, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Disinfection, Biofilms, Pseudomonas aeruginosa, Endoscopes. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, Slovenian Research and Innovation Agency (ARIS).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endoscope reprocessing is a time-consuming, multi-step process, and ongoing microbial surveillance is necessary to ensure effective reprocessing and safe storage. Despite this, traditional surveillance methods, such as cultures, are not often carried out due to time and cost constraints, providing only delayed end point results from specific locations, with no insight into biofilm formation, disinfection efficacy, or any variability related to device design. Within this study, the efficacy of plasma activated water (PAW) disinfection (and subsequent regrowth) within endoscopic test pieces was investigated using bacterial bioluminescence enabling real time and in situ monitoring of biofilm formation and treatment efficacy. Real time imaging of bioluminescent Pseudomonas aeruginosa PAO1 SEI MCS5-lite was used to track biofilm growth within translucent PVC endoscopic test pieces across regions of interest using analysis of bioluminescent intensity. Results demonstrated that biofilm accumulation was more prominent around connectors compared to other regions of the test pieces. Disinfection with PAW achieved a significant 96.45% reduction in biofilm density (determined by culture) and a 93.08% reduction in bioluminescence (relative light units). However, percentage reduction in bioluminescence ranged from 77% to 95% across regions indicating lack of uniformity of treatment. Subsequent testing with plasma activated disinfectant (PAD) showed consistent biofilm reduction across all regions, with no variability between connectors and other regions as observed with PAW and other treatments. In conclusion, bioluminescence can be used to assess efficacy of disinfectants and effect of endoscope design by tracking biofilm density in real time and in situ .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DisinfectionBiofilmsPseudomonas aeruginosaEndoscopesPlasma GasesWaterDisinfectantsLuminescent MeasurementsLuminescence

Stichwörter der Autor:innen

biofilmbioluminescencecold atmospheric plasmaendoscope disinfectionplasma activated water

Substanzen

Plasma GasesWaterDisinfectants

Autor:innen und Institutionen

  • Department for Gaseous Electronics, Jožef Stefan Institute, Ljubljana, Slovenia.
  • School of Applied Sciences, College of Health, Science and Society, University of the West of England, Bristol, United Kingdom.
  • Infection Biology & Microbiomes, Institute of Infection, Veterinary and Ecological Sciences, University of Liverpool, Liverpool, United Kingdom.
  • York Plasma Institute, School of Physics, Engineering & Technology, University of York, York, United Kingdom.

ORCID-Profile: Naomi Northage, Joshua A C Steven, Darren M Reynolds, Malcolm J Horsburgh, Robin M S Thorn

Förderung

  • Engineering and Physical Sciences Research Council
  • Slovenian Research and Innovation Agency (ARIS)

Zitieren

APA

Northage, N., Steven, J. A. C., Reynolds, D. M., Horsburgh, M. J., Walsh, J. L., & Thorn, R. M. S. (2026). Bacterial bioluminescence for the real time and in situ monitoring of endoscope disinfection using plasma activated water. Antimicrobial Agents and Chemotherapy. https://doi.org/10.1128/aac.01380-25

Vancouver

Northage N, Steven JAC, Reynolds DM, Horsburgh MJ, Walsh JL, Thorn RMS. Bacterial bioluminescence for the real time and in situ monitoring of endoscope disinfection using plasma activated water. Antimicrobial Agents and Chemotherapy. 2026. doi:10.1128/aac.01380-25

BibTeX
@article{Northage2026,
  author = {Northage, Naomi and Steven, Joshua A C and Reynolds, Darren M and Horsburgh, Malcolm J and Walsh, James L and Thorn, Robin M S},
  title = {Bacterial bioluminescence for the real time and in situ monitoring of endoscope disinfection using plasma activated water},
  journal = {Antimicrobial Agents and Chemotherapy},
  year = {2026},
  doi = {10.1128/aac.01380-25}
}
Kostenlos starten →