EUVIMEDEUVIMED entdecken
Crossref

A platform for near real-time and multiplexed monitoring of cerebrospinal fluid biomarkers and flow in neurocritical care

Fatemeh Keyvani iD, Luisa M Muller iD, Natalie Fudge iD, Bridget MacLean iD, Agosh Saini iD, Joshua Khatri, Thomas Kriesen iD, Matthias Wittstock iD, Florian A Gessler iD, Robert Langer iD, Joshua D Bernstock iD, Shriya Srinivasan iD und 1 weitere

Science Translational Medicine · 13.05.2026 · 18 (849)

DOI: 10.1126/scitranslmed.aeb1381 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Translational Medicine, erschienen am 13.05.2026. Verfasst von Fatemeh Keyvani und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Faculty of Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada. Hauptthemen laut MEDLINE: Biomarkers, Critical Care. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 92 Literaturangaben. Gefördert von: Johnson and Johnson Foundation, Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring of cerebrospinal fluid (CSF) is critical in intensive care units for the timely management of complications such as infection and mechanical malfunction in patients with external ventricular drainage systems. Current practice relies on intermittent CSF sampling for laboratory-based biomarker analysis and manual inspection, resulting in delayed reporting and intervention. To address these limitations, we developed NeuroSense, a multiplexed sensing platform that integrates with standard external ventricular drainage systems to enable near real-time monitoring of key CSF (bio)markers, including glucose, lactate, pH, and flow rate, that are essential for detecting infection and drain dysfunction. NeuroSense incorporates glucose and lactate aptamer–based electrochemical biosensors, a polydopamine pH sensor, and an impedance-based flow sensor. Validation in simulated conditions demonstrated sensor specificity, stability in human CSF for several days, and ethylene-oxide sterilization compatibility. Evaluation in patients hospitalized in intensive care unit demonstrated strong correlation with clinical reference standards. By providing near real-time bedside assessment, NeuroSense has the potential to improve temporal resolution for detection of biomarker trends and drain malfunction indicators.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BiomarkersCritical CareHumansBiosensing TechniquesHydrogen-Ion ConcentrationMonitoring, PhysiologicLactic AcidTime Factors

Substanzen

BiomarkersLactic Acid

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, Faculty of Engineering, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.
  • Department of Neurosurgery, University Medicine Rostock, 18057 Rostock, Germany.
  • Mantech Inc., Guelph, Ontario, Canada.
  • Department of Mechanical and Mechatronics Engineering, Faculty of Engineering, University of Waterloo, Waterloo, Ontario, Canada.
  • Department of Neurology, University Medicine Rostock, 18057 Rostock, Germany.
  • Department of Chemical Engineering, Massachusetts Institute of Technology, Boston, MA 02139-4307, USA.

ORCID-Profile: Fatemeh Keyvani, Luisa M Muller, Natalie Fudge, Bridget MacLean, Agosh Saini, Thomas Kriesen, Matthias Wittstock, Florian A Gessler, Robert Langer, Joshua D Bernstock, Shriya Srinivasan, Mahla Poudineh

Förderung

  • Johnson and Johnson Foundation
  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Keyvani, F., Muller, L. M., Fudge, N., MacLean, B., Saini, A., Khatri, J., Kriesen, T., Wittstock, M., Gessler, F. A., Langer, R., Bernstock, J. D., Srinivasan, S., & Poudineh, M. (2026). A platform for near real-time and multiplexed monitoring of cerebrospinal fluid biomarkers and flow in neurocritical care. Science Translational Medicine, 18(849). https://doi.org/10.1126/scitranslmed.aeb1381

Vancouver

Keyvani F, Muller LM, Fudge N, MacLean B, Saini A, Khatri J, et al. A platform for near real-time and multiplexed monitoring of cerebrospinal fluid biomarkers and flow in neurocritical care. Science Translational Medicine. 2026;18(849). doi:10.1126/scitranslmed.aeb1381

BibTeX
@article{Keyvani2026,
  author = {Keyvani, Fatemeh and Muller, Luisa M and Fudge, Natalie and MacLean, Bridget and Saini, Agosh and Khatri, Joshua and Kriesen, Thomas and Wittstock, Matthias and Gessler, Florian A and Langer, Robert and Bernstock, Joshua D and Srinivasan, Shriya and Poudineh, Mahla},
  title = {A platform for near real-time and multiplexed monitoring of cerebrospinal fluid biomarkers and flow in neurocritical care},
  journal = {Science Translational Medicine},
  year = {2026},
  volume = {18},
  number = {849},
  doi = {10.1126/scitranslmed.aeb1381}
}