EUVIMEDEUVIMED entdecken
Open Access

Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe

Vitor M Pereira iD, Pedro Lylyk iD, Nicole Cancelliere iD, Pedro N Lylyk iD, Ivan Lylyk iD, Vania Anagnostakou, Carlos Bleise, Hidehisa Nishi iD, Mark Epshtein iD, Robert M King iD, Mohammed Salman Shazeeb iD, Ajit S Puri und 7 weitere

Science Translational Medicine · 15.05.2024 · 16 (747)

DOI: 10.1126/scitranslmed.adl4497 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Translational Medicine, erschienen am 15.05.2024. Verfasst von Vitor M Pereira und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Division of Neurosurgery, St Michael's Hospital, Toronto, ON M5B 1W8, Canada. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Cerebral Arteries. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography ( n OCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The n OCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using n OCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. n OCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceCerebral ArteriesHumansMicroscopyMiniaturizationEndovascular Procedures

Autor:innen und Institutionen

  • Department of Surgery, Division of Neurosurgery, St Michael's Hospital, Toronto, ON M5B 1W8, Canada.
  • RADIS Lab, Li Ka Shing Knowledge Institute, St Michael's Hospital, Toronto, ON M5B 1W8, Canada.
  • Department of Interventional Neuroradiology, Clínica Sagrada Familia, Buenos Aires, CABA C1426, Argentina.
  • Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA 01655, USA.
  • Department of Neurosurgery, Kyoto University Graduate School of Medicine, Kyoto 606-8303, Japan.
  • Department of Neurosurgery, Kaiser Permanente Fontana Medical Center, Fontana, CA 92335, USA.

ORCID-Profile: Vitor M Pereira, Pedro Lylyk, Nicole Cancelliere, Pedro N Lylyk, Ivan Lylyk, Hidehisa Nishi, Mark Epshtein, Robert M King, Mohammed Salman Shazeeb, Conrad W Liang, Ricardo A Hanel, Thomas R Marotta, Demetrius K Lopes, Matthew J Gounis, Giovanni J Ughi

Förderung

  • NINDS NIH HHS

Zitieren

APA

Pereira, V. M., Lylyk, P., Cancelliere, N., Lylyk, P. N., Lylyk, I., Anagnostakou, V., Bleise, C., Nishi, H., Epshtein, M., King, R. M., Shazeeb, M. S., Puri, A. S., Liang, C. W., Hanel, R. A., Spears, J., Marotta, T. R., Lopes, D. K., Gounis, M. J., & Ughi, G. J. (2024). Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe. Science Translational Medicine, 16(747). https://doi.org/10.1126/scitranslmed.adl4497

Vancouver

Pereira VM, Lylyk P, Cancelliere N, Lylyk PN, Lylyk I, Anagnostakou V, et al. Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe. Science Translational Medicine. 2024;16(747). doi:10.1126/scitranslmed.adl4497

BibTeX
@article{Pereira2024,
  author = {Pereira, Vitor M and Lylyk, Pedro and Cancelliere, Nicole and Lylyk, Pedro N and Lylyk, Ivan and Anagnostakou, Vania and Bleise, Carlos and Nishi, Hidehisa and Epshtein, Mark and King, Robert M and Shazeeb, Mohammed Salman and Puri, Ajit S and Liang, Conrad W and Hanel, Ricardo A and Spears, Julian and Marotta, Thomas R and Lopes, Demetrius K and Gounis, Matthew J and Ughi, Giovanni J},
  title = {Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe},
  journal = {Science Translational Medicine},
  year = {2024},
  volume = {16},
  number = {747},
  doi = {10.1126/scitranslmed.adl4497}
}
Kostenlos starten →