EUVIMEDEUVIMED entdecken
Crossref

Stabilizing telerobotic endobronchial imaging and interventions in breathing lungs with a helical brace

Tinghua Zhang iD, Sishen Yuan iD, Chao Xu iD, Ruiyang Zhang iD, Jarinyagon Chantawannakul iD, Botao Lin iD, Chenyu Shang iD, Di Mei iD, Sze Hang Calvin Ng iD, Pierre E Dupont iD, Hongliang Ren iD, Wu Yuan iD

Science Robotics · 2026

DOI: 10.1126/scirobotics.aed1960 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Robotics, 2026. Verfasst von Tinghua Zhang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Chinese University of Hong Kong, Hong Kong, China. Hauptthemen laut MEDLINE: Lung, Bronchi, Bronchoscopy. Die Arbeit nennt 77 Literaturangaben. Gefördert von: Science, Technology, and Innovation Commission (STIC) of Shenzhen Municipality, Innovation and Technology Fund (ITF) of Hong Kong SAR, Research Grants Council (RGC) of Hong Kong SAR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Physiological motion in dynamic luminal organs, such as respiration-induced lung displacement, compromises the stability of tool-tissue interaction during telerobotic endoluminal imaging and interventions. However, existing devices for stabilizing the distal end of a catheter or endoscope face critical limitations: Rigid shape-locking mechanisms risk pressure-induced trauma, electrical hazard, and thermal injury, whereas balloon-based designs obstruct luminal patency. Moreover, they lack sufficient adjustable-diameter range for anatomies such as the bronchial tree. In this work, we present a reconfigurable helical brace that overcomes these challenges. Constructed of rotationally stacking tubular modules of asymmetric stiffness, the helical brace achieved up to almost 10 times diameter tunability (3.0 to 29.3 millimeters), enabling adaptive anchoring across diverse bronchial diameters. The established brace in a dynamic bronchus phantom reduced respiration-induced catheter displacement by about 96.0% while preserving more than 97.4% luminal flow conductance. Ex vivo and in vivo bronchial studies confirmed safety under prolonged radial loading, with no notable surface trauma or deep tissue injury observed. We demonstrate a helically braced telerobotic manipulator that can operate with submillimeter control accuracy in dynamic environments, enabling targeted transbronchial needle interventions in live porcine models, including drug delivery, bronchus puncture, and fluid aspiration. In addition, in vivo studies on porcine lungs showed that the brace-aided telerobotic catheter enhances the stability of optical coherence tomography imaging, effectively achieving respiratory motion-free conditions. This patency-preserving brace enhances stabilization without compromising physiological function and safety, ensuring accurate telerobotic operations in dynamic luminal environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LungBronchiBronchoscopyEquipment DesignAnimalsHumansRespirationPhantoms, ImagingSwineCatheters

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Chinese University of Hong Kong, Hong Kong, China.
  • Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong, China.
  • Department of Surgery, Chinese University of Hong Kong, Hong Kong, China.
  • Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.

ORCID-Profile: Tinghua Zhang, Sishen Yuan, Chao Xu, Ruiyang Zhang, Jarinyagon Chantawannakul, Botao Lin, Chenyu Shang, Di Mei, Sze Hang Calvin Ng, Pierre E Dupont, Hongliang Ren, Wu Yuan

Förderung

  • Science, Technology, and Innovation Commission (STIC) of Shenzhen Municipality
  • Innovation and Technology Fund (ITF) of Hong Kong SAR
  • Research Grants Council (RGC) of Hong Kong SAR
  • NSFC Young Scientists Fund - Category A
  • Hong Kong Research Grants Council Research Impact Fund
  • Hong Kong Research Grants Council Collaborative Research Fund
  • NSFC

Zitieren

APA

Zhang, T., Yuan, S., Xu, C., Zhang, R., Chantawannakul, J., Lin, B., Shang, C., Mei, D., Ng, S. H. C., Dupont, P. E., Ren, H., & Yuan, W. (2026). Stabilizing telerobotic endobronchial imaging and interventions in breathing lungs with a helical brace. Science Robotics. https://doi.org/10.1126/scirobotics.aed1960

Vancouver

Zhang T, Yuan S, Xu C, Zhang R, Chantawannakul J, Lin B, et al. Stabilizing telerobotic endobronchial imaging and interventions in breathing lungs with a helical brace. Science Robotics. 2026. doi:10.1126/scirobotics.aed1960

BibTeX
@article{Zhang2026,
  author = {Zhang, Tinghua and Yuan, Sishen and Xu, Chao and Zhang, Ruiyang and Chantawannakul, Jarinyagon and Lin, Botao and Shang, Chenyu and Mei, Di and Ng, Sze Hang Calvin and Dupont, Pierre E and Ren, Hongliang and Yuan, Wu},
  title = {Stabilizing telerobotic endobronchial imaging and interventions in breathing lungs with a helical brace},
  journal = {Science Robotics},
  year = {2026},
  doi = {10.1126/scirobotics.aed1960}
}
Kostenlos starten →