Telemetric calorimetry for wireless continuous reaction profiling
Science · 19.11.2026 · 394 (6826) · 875-883
DOI: 10.1126/science.aei7840 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science, erschienen am 19.11.2026. Verfasst von Sukwoo Lee und 8 weiteren Autor:innen. Die Arbeit nennt 59 Literaturangaben. Gefördert von: National Science Foundation, National Institute of General Medical Sciences, National Science Foundation Graduate Research Fellowship Program.
Abstract (Originalsprache)
Real-time monitoring of chemical reactions is often achieved with specialized instrumentation along with custom-designed reactors or intrusive sampling. In this study, we introduce reaction telemetry, a wireless analytical strategy that enables remote, nonintrusive monitoring directly within operating reaction vessels. This approach uses light-powered microelectronic devices that communicate optically and function as autonomous sensing elements. We demonstrate continuous calorimetric measurements across diverse chemical reactions relevant to pharmaceutical and fine chemical synthesis, including photochemical and electrochemical systems, providing access to reaction kinetics under native operating conditions with subsecond temporal resolution. The resulting measurements will support catalyst evaluation, safety assessment, and mechanistic investigation and will accelerate data-driven reaction discovery. By embedding analytical functionality directly within reaction vessels, reaction telemetry establishes a general framework for information-rich observation of chemical processes across research, development, and education.
Förderung
- National Science Foundation
- National Institute of General Medical Sciences
- National Science Foundation Graduate Research Fellowship Program
- Kavli Institute at Cornell for Nanoscale Science
- Kwanjeong Educational Foundation
Zitieren
APA
Lee, S., Weingarten, E. A., Reynolds, M. F., Sun, K., Cortese, A. J., Davies, H. M. L., Molnar, A. C., McEuen, P. L., & Lin, S. (2026). Telemetric calorimetry for wireless continuous reaction profiling. Science, 394(6826), 875-883. https://doi.org/10.1126/science.aei7840
Vancouver
Lee S, Weingarten EA, Reynolds MF, Sun K, Cortese AJ, Davies HML, et al. Telemetric calorimetry for wireless continuous reaction profiling. Science. 2026;394(6826):875-883. doi:10.1126/science.aei7840
BibTeX
@article{Lee2026,
author = {Lee, Sukwoo and Weingarten, Evan A. and Reynolds, Michael F. and Sun, Kevin and Cortese, Alejandro J. and Davies, Huw M. L. and Molnar, Alyosha C. and McEuen, Paul L. and Lin, Song},
title = {Telemetric calorimetry for wireless continuous reaction profiling},
journal = {Science},
year = {2026},
volume = {394},
number = {6826},
pages = {875--883},
doi = {10.1126/science.aei7840}
}