High cooling performance in a double-loop electrocaloric heat pump
Science · 17.11.2023 · 382 (6672) · 801-805
DOI: 10.1126/science.adi5477 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science, erschienen am 17.11.2023. Verfasst von Junning Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: Materials Research and Technology Department, Luxembourg Institute of Science and Technology, Belvaux L-4422, Luxembourg. Die Arbeit wurde bisher 149-mal zitiert (Crossref) und nennt 53 Literaturangaben.
Abstract (Originalsprache)
Cooling through solid-state electrocaloric materials is an attractive replacement for vapor compression. Despite recent efforts, devices that are potentially commercially competitive have not been developed. We present an electrocaloric cooler with a maximum temperature span of 20.9 kelvin and a maximum cooling power of 2.1 watts under the moderate applied electric field of 10 volts per micrometer without any observed breakdown. Moreover, the maximum coefficient of performance, even taking into account energy expended on fluid pumping, reaches 54% of Carnot’s efficiency as long as energy is properly recovered. We believe that this demonstration shows electrocaloric cooling to be a very promising alternative to vapor compression cooling.
Autor:innen und Institutionen
- Materials Research and Technology Department, Luxembourg Institute of Science and Technology, Belvaux L-4422, Luxembourg.
- University of Luxembourg, Esch-sur-Alzette L-4365, Luxembourg.
- Murata Manufacturing Co., Nagaokakyo, Kyoto 617-8555, Japan.
ORCID-Profile: Junning Li, Veronika Kovacova, Uros Prah, Ashwath Aravindhan, Torsten Granzow, Tomoyasu Usui, Sakyo Hirose, Emmanuel Defay
Zitieren
APA
Li, J., Torelló, A., Kovacova, V., Prah, U., Aravindhan, A., Granzow, T., Usui, T., Hirose, S., & Defay, E. (2023). High cooling performance in a double-loop electrocaloric heat pump. Science, 382(6672), 801-805. https://doi.org/10.1126/science.adi5477
Vancouver
Li J, Torelló A, Kovacova V, Prah U, Aravindhan A, Granzow T, et al. High cooling performance in a double-loop electrocaloric heat pump. Science. 2023;382(6672):801-805. doi:10.1126/science.adi5477
BibTeX
@article{Li2023,
author = {Li, Junning and Torelló, Alvar and Kovacova, Veronika and Prah, Uros and Aravindhan, Ashwath and Granzow, Torsten and Usui, Tomoyasu and Hirose, Sakyo and Defay, Emmanuel},
title = {High cooling performance in a double-loop electrocaloric heat pump},
journal = {Science},
year = {2023},
volume = {382},
number = {6672},
pages = {801--805},
doi = {10.1126/science.adi5477}
}
EUVIMED