EUVIMEDEUVIMED entdecken
Crossref

Tremor signals during fluid injection are generated by fault slip

Shankho Niyogi iD, Abhijit Ghosh iD, Abhash Kumar, Richard W Hammack

Science · 04.08.2023 · 381 (6657) · 553-558

DOI: 10.1126/science.adh1331 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science, erschienen am 04.08.2023. Verfasst von Shankho Niyogi und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of California, Riverside, CA, USA. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 64 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Seismic tremor signals, also known as long-period, long-duration signals, have been reported in several locations where fluid injection for enhanced oil and gas exploration is taking place. However, the origin of these signals remains poorly constrained. We studied seismic tremor signals in Wellington Field, Kansas, using a seismic array during a carbon dioxide injection program. We show that these signals are generated below the surface during the time of carbon dioxide injection. They have a distinct spectral signature, similar to those observed in glacial and volcanic environments. The tremor sources are located near the injection site and aligned with preexisting faults. Modeling results imply that such tremors are generated by frictional slip on fault. These observations may reveal an important deformation mode, which is useful for studying associated stress, seismicity, and triggering, as well as for tracking fault activities during injection operations of all fluids, including supercritical carbon dioxide.

Autor:innen und Institutionen

  • University of California, Riverside, CA, USA.
  • National Energy Technology Laboratory, Pittsburgh, PA, USA.

ORCID-Profile: Shankho Niyogi, Abhijit Ghosh

Zitieren

APA

Niyogi, S., Ghosh, A., Kumar, A., & Hammack, R. W. (2023). Tremor signals during fluid injection are generated by fault slip. Science, 381(6657), 553-558. https://doi.org/10.1126/science.adh1331

Vancouver

Niyogi S, Ghosh A, Kumar A, Hammack RW. Tremor signals during fluid injection are generated by fault slip. Science. 2023;381(6657):553-558. doi:10.1126/science.adh1331

BibTeX
@article{Niyogi2023,
  author = {Niyogi, Shankho and Ghosh, Abhijit and Kumar, Abhash and Hammack, Richard W},
  title = {Tremor signals during fluid injection are generated by fault slip},
  journal = {Science},
  year = {2023},
  volume = {381},
  number = {6657},
  pages = {553--558},
  doi = {10.1126/science.adh1331}
}
Kostenlos starten →