EUVIMEDEUVIMED entdecken
Open Access

Mitigating lateral sensing blind spots: A dual-segment bronchoscopic robot with a bioinspired skin

Qiqi Pan iD, Wenke Duan, Jingjing Luo iD, Lei Wang iD, Shijie Guo iD, Yongfei Feng iD, Hongbo Wang iD

Science Advances · 09.10.2026 · 12 (41)

DOI: 10.1126/sciadv.aeh9503 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science Advances, erschienen am 09.10.2026. Verfasst von Qiqi Pan und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai & 200433, China. Hauptthemen laut MEDLINE: Bronchoscopy, Robotics, Robotic Surgical Procedures. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lateral force blind spots frequently trigger airway injuries during robotic bronchoscopy. Traditional sensing approaches lack fine spatial resolution, and single-segment robots suffer poor posture adjustment flexibility, worsening unmonitored tissue contact. We integrate a snake-scale-inspired 64-channel gradient piezoelectric film with a dual-segment manipulator to resolve lateral blind spots for secure bronchial navigation. The conformally wrapped sensor delivers fast ( 0.98, RMSE < 0.145 N, CV < 2%) and filters bending pseudo-forces. The dual-segment design enables coordinated proximal-distal motion to avoid overcontact in tortuous lumens. Phantom and ex vivo porcine lung tests confirm real-time force localization, 5.0 N safety alarms, and autonomous tuning to keep contact forces below 3.0 N. This synergistic robot-sensor design supplies a translatable safety control strategy for flexible surgical manipulators.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BronchoscopyRoboticsRobotic Surgical ProceduresAnimalsSwineBiomimeticsEquipment DesignHumansSkin

Autor:innen und Institutionen

  • College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai & 200433, China.
  • Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen & 518055, China.
  • School of Electronic Information, Central South University, Changsha & 410083, China.
  • School of Mechanical Engineering, Hebei University of Technology, Tianjin & 300400, China.
  • Faculty of Mechanical Engineering and Mechanics, Ningbo University, Ningbo & 315211, China.

ORCID-Profile: Qiqi Pan, Jingjing Luo, Lei Wang, Shijie Guo, Yongfei Feng, Hongbo Wang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Pan, Q., Duan, W., Luo, J., Wang, L., Guo, S., Feng, Y., & Wang, H. (2026). Mitigating lateral sensing blind spots: A dual-segment bronchoscopic robot with a bioinspired skin. Science Advances, 12(41). https://doi.org/10.1126/sciadv.aeh9503

Vancouver

Pan Q, Duan W, Luo J, Wang L, Guo S, Feng Y, et al. Mitigating lateral sensing blind spots: A dual-segment bronchoscopic robot with a bioinspired skin. Science Advances. 2026;12(41). doi:10.1126/sciadv.aeh9503

BibTeX
@article{Pan2026,
  author = {Pan, Qiqi and Duan, Wenke and Luo, Jingjing and Wang, Lei and Guo, Shijie and Feng, Yongfei and Wang, Hongbo},
  title = {Mitigating lateral sensing blind spots: A dual-segment bronchoscopic robot with a bioinspired skin},
  journal = {Science Advances},
  year = {2026},
  volume = {12},
  number = {41},
  doi = {10.1126/sciadv.aeh9503}
}
Kostenlos starten →