Fachartikel in der Zeitschrift Science Advances, 2025. Verfasst von Liyang Wang und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA. Hauptthemen laut MEDLINE: Nitric Oxide, Inflammation, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 89 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Nitric oxide (NO) released endogenously by induced NO synthase (iNOS) in macrophages is a key regulatory biomarker for wound inflammation. Detecting NO directly on the wound bed is challenging due to its short half-life time (6 to 50 seconds), low physiological concentration (nanomolar to micromolar), and interferences in the complex wound environment. Here, we present a compliant, multiplexed, electrochemical, real-time, localized, inflammation-tracking NO sensor (MERLIN) array for in vivo spatiotemporal measurement of NO, with high sensitivity (883 ± 283 nanoamperes per micromolar per square centimeter); selectivity against nitrites (~27,900-fold), ascorbic acid (~3800-fold), and uric acid (~6900-fold); and low limit of detection (~8.00 nM). MERLIN spatiotemporally tracked NO on rat skin wounds for 7 days, and results indicated that NO peaks on day 3, in line with previously reported iNOS activity. MERLIN allows spatial mapping of the NO gradient across the wound bed, which can be used to provide diagnostic information to assist wound care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Materials Science and Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA.
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA.
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15260, USA.
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219, USA.
- College of Osteopathic Medicine, Lake Erie College of Osteopathic Medicine, Greensburg, PA 15601, USA.
ORCID-Profile: Liyang Wang, Yingqiao Wang, Daniel San Roman, Samuel Gershanok, Reem Khan, Clint Skillen, Shanae Butler, Stephen F Badylak, Devora Cohen-Karni, Tzahi Cohen-Karni
Zitieren
APA
Wang, L., Wang, Y., Bartlett, M., Roman, D. S., Balakrishnan, G., Gershanok, S., Khan, R., Skillen, C., Butler, S., Kulkarni, M., Badylak, S. F., Cohen-Karni, D., Brown, B., & Cohen-Karni, T. (2025). Wound state monitoring by multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN). Science Advances. https://doi.org/10.1126/sciadv.adv2385
Vancouver
Wang L, Wang Y, Bartlett M, Roman DS, Balakrishnan G, Gershanok S, et al. Wound state monitoring by multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN). Science Advances. 2025. doi:10.1126/sciadv.adv2385
BibTeX
@article{Wang2025,
author = {Wang, Liyang and Wang, Yingqiao and Bartlett, Mabel and Roman, Daniel San and Balakrishnan, Gaurav and Gershanok, Samuel and Khan, Reem and Skillen, Clint and Butler, Shanae and Kulkarni, Mangesh and Badylak, Stephen F and Cohen-Karni, Devora and Brown, Bryan and Cohen-Karni, Tzahi},
title = {Wound state monitoring by multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN)},
journal = {Science Advances},
year = {2025},
doi = {10.1126/sciadv.adv2385}
}
EUVIMED