Compact highly sensitive photothermal RT-LAMP chip for simultaneous multidisease detection
Science Advances · 15.11.2024 · 10 (46)
DOI: 10.1126/sciadv.adq2899 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 15.11.2024. Verfasst von Wenshang Guo und 12 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Developing instant detection systems with disease diagnostic capabilities holds immense importance for remote or resource-limited areas. However, the task of creating these systems—which are simultaneously easy to operate, rapid in detection, and cost-effective—remains a challenge. In this study, we present a compact highly sensitive photothermal reverse transcriptase–loop-mediated isothermal amplification (RT-LAMP) chip (SPRC) designed for the detection of multiple diseases. The nucleic acid (NA) amplification on the chip is achieved through LAMP driven by either LED illumination or simple sunlight focusing. SPRC performs sample addition and amplification within a limited volume and autonomous enrichment of NA during the sample addition process, achieving a limit of detection (LOD) as low as 0.2 copies per microliter. Through 120 clinical samples, we achieved an accuracy of 95%, with a specificity exceeding 97.5%. Overall, SPRC has achieved promising progress in the application of point-of-care testing (POCT) by using light energy to simultaneously detect multiple diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China.
- Department of Laboratory Diagnosis, The First Affiliated Hospital of Harbin Medical University, Harbin 150001, China.
ORCID-Profile: Wenshang Guo, Ye Tao, Hongwei Zhou, Zhenyou Ge, Haizhou Zhou, Yukun Ren
Zitieren
APA
Guo, W., Tao, Y., Yang, R., Mao, K., Zhou, H., Xu, M., Sun, T., Li, X., Shi, C., Ge, Z., Xue, R., Zhou, H., & Ren, Y. (2024). Compact highly sensitive photothermal RT-LAMP chip for simultaneous multidisease detection. Science Advances, 10(46). https://doi.org/10.1126/sciadv.adq2899
Vancouver
Guo W, Tao Y, Yang R, Mao K, Zhou H, Xu M, et al. Compact highly sensitive photothermal RT-LAMP chip for simultaneous multidisease detection. Science Advances. 2024;10(46). doi:10.1126/sciadv.adq2899
BibTeX
@article{Guo2024,
author = {Guo, Wenshang and Tao, Ye and Yang, Ruizhe and Mao, Kaihao and Zhou, Hongwei and Xu, Minghui and Sun, Tie and Li, Xiao and Shi, Changrui and Ge, Zhenyou and Xue, Rui and Zhou, Haizhou and Ren, Yukun},
title = {Compact highly sensitive photothermal RT-LAMP chip for simultaneous multidisease detection},
journal = {Science Advances},
year = {2024},
volume = {10},
number = {46},
doi = {10.1126/sciadv.adq2899}
}
EUVIMED