Fachartikel in der Zeitschrift Science Advances, erschienen am 30.08.2024. Verfasst von Tinghua Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The complex anatomy of internal luminal organs, like bronchioles, poses challenges for endoscopic optical coherence tomography (OCT). These challenges include limited steerability for targeted imaging and nonuniform rotation distortion (NURD) with proximal scanning. Using rotary micromotors for distal scanning could address NURD but raises concerns about electrical safety and costs. We present pneumaOCT, the first pneumatic OCT endoscope, comprising a steerable catheter with a soft pneumatic actuator and an imaging probe with a miniature pneumatic turbine. With a diameter of 2.8 mm, pneumaOCT allows for a bending angle of up to 237°, facilitating navigation through narrow turns. The pneumatic turbine enables adjustable imaging speeds from 51 to 446 revolutions per second. We demonstrate the pneumaOCT in vivo imaging of mouse esophagus and colon, as well as targeted and distortion-free imaging of peripheral bronchioles in a bronchial phantom and a porcine lung. This advancement substantially improves endoscopic OCT for navigational imaging in curved and narrow lumens.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceAnimalsMiceSwinePhantoms, ImagingEsophagusColonEndoscopyBronchioles

Autor:innen und Institutionen

  • Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
  • Department of Surgery, The Chinese University of Hong Kong, Hong Kong SAR, China.

ORCID-Profile: Tinghua Zhang, Sishen Yuan, Chao Xu, Peng Liu, Hing-Chiu Chang, Sze Hang Calvin Ng, Hongliang Ren, Wu Yuan

Zitieren

APA

Zhang, T., Yuan, S., Xu, C., Liu, P., Chang, H. C., Ng, S. H. C., Ren, H., & Yuan, W. (2024). PneumaOCT: Pneumatic optical coherence tomography endoscopy for targeted distortion-free imaging in tortuous and narrow internal lumens. Science Advances, 10(35). https://doi.org/10.1126/sciadv.adp3145

Vancouver

Zhang T, Yuan S, Xu C, Liu P, Chang HC, Ng SHC, et al. PneumaOCT: Pneumatic optical coherence tomography endoscopy for targeted distortion-free imaging in tortuous and narrow internal lumens. Science Advances. 2024;10(35). doi:10.1126/sciadv.adp3145

BibTeX
@article{Zhang2024,
  author = {Zhang, Tinghua and Yuan, Sishen and Xu, Chao and Liu, Peng and Chang, Hing-Chiu and Ng, Sze Hang Calvin and Ren, Hongliang and Yuan, Wu},
  title = {PneumaOCT: Pneumatic optical coherence tomography endoscopy for targeted distortion-free imaging in tortuous and narrow internal lumens},
  journal = {Science Advances},
  year = {2024},
  volume = {10},
  number = {35},
  doi = {10.1126/sciadv.adp3145}
}
Kostenlos starten →