Soft, bioresorbable, transparent microelectrode arrays for multimodal spatiotemporal mapping and modulation of cardiac physiology
Science Advances · 07.07.2023 · 9 (27)
DOI: 10.1126/sciadv.adi0757 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 07.07.2023. Verfasst von Zhiyuan Chen und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA. Hauptthemen laut MEDLINE: Absorbable Implants, Heart Diseases. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Transparent microelectrode arrays (MEAs) that allow multimodal investigation of the spatiotemporal cardiac characteristics are important in studying and treating heart disease. Existing implantable devices, however, are designed to support chronic operational lifetimes and require surgical extraction when they malfunction or are no longer needed. Meanwhile, bioresorbable systems that can self-eliminate after performing temporary functions are increasingly attractive because they avoid the costs/risks of surgical extraction. We report the design, fabrication, characterization, and validation of a soft, fully bioresorbable, and transparent MEA platform for bidirectional cardiac interfacing over a clinically relevant period. The MEA provides multiparametric electrical/optical mapping of cardiac dynamics and on-demand site-specific pacing to investigate and treat cardiac dysfunctions in rat and human heart models. The bioresorption dynamics and biocompatibility are investigated. The device designs serve as the basis for bioresorbable cardiac technologies for potential postsurgical monitoring and treating temporary patient pathological conditions in certain clinical scenarios, such as myocardial infarction, ischemia, and transcatheter aortic valve replacement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Biomedical Engineering, The George Washington University, Washington, DC 20052, USA.
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA.
- MedStar Georgetown University Hospital, Washington, DC 20037, USA.
- Department of Medicine (Cardiology), Northwestern University, Chicago, IL 60611, USA.
ORCID-Profile: Zhiyuan Chen, Zexu Lin, Sofian N Obaid, Eric Rytkin, Sharon A George, Christopher Bach, Miya Liu, Jessica LaPiano, Helen Knight, Anthony Aduwari, Igor R Efimov, Luyao Lu
Zitieren
APA
Chen, Z., Lin, Z., Obaid, S. N., Rytkin, E., George, S. A., Bach, C., Madrid, M., Liu, M., LaPiano, J., Fehr, A., Shi, X., Quirion, N., Russo, B., Knight, H., Aduwari, A., Efimov, I. R., & Lu, L. (2023). Soft, bioresorbable, transparent microelectrode arrays for multimodal spatiotemporal mapping and modulation of cardiac physiology. Science Advances, 9(27). https://doi.org/10.1126/sciadv.adi0757
Vancouver
Chen Z, Lin Z, Obaid SN, Rytkin E, George SA, Bach C, et al. Soft, bioresorbable, transparent microelectrode arrays for multimodal spatiotemporal mapping and modulation of cardiac physiology. Science Advances. 2023;9(27). doi:10.1126/sciadv.adi0757
BibTeX
@article{Chen2023,
author = {Chen, Zhiyuan and Lin, Zexu and Obaid, Sofian N and Rytkin, Eric and George, Sharon A and Bach, Christopher and Madrid, Micah and Liu, Miya and LaPiano, Jessica and Fehr, Amy and Shi, Xinyu and Quirion, Nathaniel and Russo, Benjamin and Knight, Helen and Aduwari, Anthony and Efimov, Igor R and Lu, Luyao},
title = {Soft, bioresorbable, transparent microelectrode arrays for multimodal spatiotemporal mapping and modulation of cardiac physiology},
journal = {Science Advances},
year = {2023},
volume = {9},
number = {27},
doi = {10.1126/sciadv.adi0757}
}
EUVIMED