A movable unshielded magnetocardiography system
Science Advances · 31.03.2023 · 9 (13)
DOI: 10.1126/sciadv.adg1746 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 31.03.2023. Verfasst von Wei Xiao und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Pe…. Hauptthemen laut MEDLINE: Magnetocardiography, Heart Diseases. Die Arbeit wurde bisher 122-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Magnetocardiography (MCG), which uses high-sensitivity magnetometers to record magnetic field signals generated by electrical activity in the heart, is a noninvasive method for evaluating heart diseases such as arrhythmia and ischemia. The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments. These requirements limit MCG applications, such as exercise MCG tests and long-term MCG observations, which are useful for early detections of heart diseases. Here, we introduce a movable MCG system that can clearly record MCG signals of freely behaving participants in an unshielded environment. On the basis of optically pumped magnetometers with a sensitivity of 140 fT/Hz 1/2 , we successfully demonstrated the resting MCG and the exercise MCG tests. Our method is promising to realize a practical movable multichannel unshielded MCG system that nearly sets no limits to participants and brings another kind of insight into the medical diagnosis of heart disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China.
ORCID-Profile: Wei Xiao, Chenxi Sun, Liang Shen, Meng Liu, Yulong Wu, Xiyu Liu, Teng Wu, Xiang Peng, Hong Guo
Zitieren
APA
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023). A movable unshielded magnetocardiography system. Science Advances, 9(13). https://doi.org/10.1126/sciadv.adg1746
Vancouver
Xiao W, Sun C, Shen L, Feng Y, Liu M, Wu Y, et al. A movable unshielded magnetocardiography system. Science Advances. 2023;9(13). doi:10.1126/sciadv.adg1746
BibTeX
@article{Xiao2023,
author = {Xiao, Wei and Sun, Chenxi and Shen, Liang and Feng, Yulong and Liu, Meng and Wu, Yulong and Liu, Xiyu and Wu, Teng and Peng, Xiang and Guo, Hong},
title = {A movable unshielded magnetocardiography system},
journal = {Science Advances},
year = {2023},
volume = {9},
number = {13},
doi = {10.1126/sciadv.adg1746}
}
EUVIMED