Real-time viscoelastic deformability cytometry: High-throughput mechanical phenotyping of liquid and solid biopsies
Science Advances · 06.12.2024 · 10 (49)
DOI: 10.1126/sciadv.abj1133 ↗Kurz gefasst
Fachartikel in der Zeitschrift Science Advances, erschienen am 06.12.2024. Verfasst von Mohammad Asghari und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland. Hauptthemen laut MEDLINE: Single-Cell Analysis. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
In principle, the measurement of mechanical property differences between cancer cells and their benign counterparts enables the detection, diagnosis, and classification of diseases. Despite the existence of various mechanophenotyping methods, the ability to perform high-throughput single-cell deformability measurements on liquid and/or solid tissue biopsies remains an unmet challenge within clinical settings. To address this issue, we present an ultrahigh-throughput viscoelastic microfluidic platform able to measure the mechanical properties of single cells at rates of up to 100,000 cells per second (and up to 10,000 cells per second in real time). To showcase the utility of the presented platform in clinical scenarios, we perform single-cell phenotyping of both liquid and solid tumor biopsies, cytoskeletal drug analysis, and identification of malignant lymphocytes in peripheral blood samples. Our viscoelastic microfluidic methodology offers opportunities for high-throughput, label-free single-cell analysis, with diverse applications in clinical diagnostics and personalized medicine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland.
- Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden.
- Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland.
- Department of Neurology, University Hospital Zürich, 8091 Zürich, Switzerland.
- Clinical Neuroscience Center, University of Zürich, 8091 Zürich, Switzerland.
- Department of Mechanical and Production Engineering, Aarhus University, Aarhus, Denmark.
ORCID-Profile: Mohammad Asghari, Sarah Duclos Ivetich, Morteza Aramesh, Yingchao Meng, Rong Xu, Monika Colombo, Tobias Weiss, Stefan Balabanov, Stavros Stavrakis, Andew J deMello
Zitieren
APA
Asghari, M., Ivetich, S. D., Aslan, M. K., Aramesh, M., Melkonyan, O., Meng, Y., Xu, R., Colombo, M., Weiss, T., Balabanov, S., Stavrakis, S., & deMello, A. J. (2024). Real-time viscoelastic deformability cytometry: High-throughput mechanical phenotyping of liquid and solid biopsies. Science Advances, 10(49). https://doi.org/10.1126/sciadv.abj1133
Vancouver
Asghari M, Ivetich SD, Aslan MK, Aramesh M, Melkonyan O, Meng Y, et al. Real-time viscoelastic deformability cytometry: High-throughput mechanical phenotyping of liquid and solid biopsies. Science Advances. 2024;10(49). doi:10.1126/sciadv.abj1133
BibTeX
@article{Asghari2024,
author = {Asghari, Mohammad and Ivetich, Sarah Duclos and Aslan, Mahmut Kamil and Aramesh, Morteza and Melkonyan, Oleksandr and Meng, Yingchao and Xu, Rong and Colombo, Monika and Weiss, Tobias and Balabanov, Stefan and Stavrakis, Stavros and deMello, Andew J},
title = {Real-time viscoelastic deformability cytometry: High-throughput mechanical phenotyping of liquid and solid biopsies},
journal = {Science Advances},
year = {2024},
volume = {10},
number = {49},
doi = {10.1126/sciadv.abj1133}
}
EUVIMED