Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial
Journal of Sport Rehabilitation · 01.08.2024 · 33 (6) · 423-436
DOI: 10.1123/jsr.2023-0253 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Sport Rehabilitation, erschienen am 01.08.2024. Verfasst von Brahim Agrebi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Higher Institute of Sport and Physical Education of Ksar Said, Tunis, Tunisia. Hauptthemen laut MEDLINE: Torque, Resistance Training, Range of Motion, Articular, Shoulder. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
Context
The aim of this study was to investigate the effects of 8-week ballistic-strength-training program using a validated specific throwing device (ie, Arm/Shoulder Specific Strength Device), on isokinetic shoulders’ rotation muscle-torques and ratios as well as range of motion in team handball players.
Design
A repeated-measures experimental design with a randomized controlled trial was used.
Methods
Twenty-six high-level competitive male U-19 team handball players were randomly assigned into training (TG, n = 15) and control (n = 11) groups. The TG undertook a twice a week for 8-week periodized throws program with an individually predetermined optimal load. The program incorporated shackled eccentric and concentric exercises using the Arm/Shoulder Specific Strength Device. Peak torques, functional, and conventional ratios for both arms at different angular velocities (60°·s −1 , 180°·s −1 , and 300°·s −1 ) were assessed over time and between groups, using an isokinetic dynamometer.
Results
A significant improvement for TG ( P < .01; d = 1.13 [moderate]; +20.2%) of the concentric peak torques for dominant arm in external rotation was observed at 300°·s −1 . Significant ( P < .05–.01) increases were also noted for nondominant arm at the 3 studied angular velocities. In addition, 300°·s −1 eccentric peak torques of the dominant arm and nondominant arm have significantly improved for both external and internal rotations ( P < .05; d = .99 [ moderate ] and d = 1.21 [large]; +15.7% and + 17.9%, respectively) with small changes at the other angular assessed velocities. Posttraining, TG’s dominant arm showed significant improvements ( P < .05–.01) in functional and conventional ratios at all velocities. Notably, significant differences ( P < .05–.01) were observed at 60°·s −1 and across all velocities when comparing the TG with the control group. TG showed significant increase for internal rotation and external rotation shoulder range of motions ( P < .05; d = 1.22–1.27 [ large ]), +5.0% and +7.7%, respectively).
Conclusions
The specific 8-week throwing training program on the Arm/Shoulder Specific Strength Device showed significant performance improvements in almost all assessed isokinetic concentric and eccentric peak torques as well as internal and external range of motion increase for both arms while ensuring rotator cuff torque ratios and shoulder mobility in team handball real sport-specific condition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Higher Institute of Sport and Physical Education of Ksar Said, Tunis, Tunisia.
- Research Unit "Sport Sciences, Health and Movement," Higher Institute of Sports and Physical Education of Kef, University of Jendouba, Kef, Tunisia.
- Training Department, Police Academy, Police College, Doha, Qatar.
- Higher Institute of Technological Studies of Rades, Radès, Tunisia.
- Tunisian Research Laboratory "Sport Performance Optimization," National Center of Medicine and Science in Sports (CNMSS), Tunis, Tunisia.
ORCID-Profile: Brahim Agrebi, Wissem Dhahbi, Hatem Abidi, Sofien Kasmi, Mokhtar Chtara, Karim Chamari
Zitieren
APA
Agrebi, B., Dhahbi, W., Abidi, H., Kasmi, S., Houas, N., Chtara, M., & Chamari, K. (2024). Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial. Journal of Sport Rehabilitation, 33(6), 423-436. https://doi.org/10.1123/jsr.2023-0253
Vancouver
Agrebi B, Dhahbi W, Abidi H, Kasmi S, Houas N, Chtara M, et al. Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial. Journal of Sport Rehabilitation. 2024;33(6):423-436. doi:10.1123/jsr.2023-0253
BibTeX
@article{Agrebi2024,
author = {Agrebi, Brahim and Dhahbi, Wissem and Abidi, Hatem and Kasmi, Sofien and Houas, Narjes and Chtara, Mokhtar and Chamari, Karim},
title = {Isokinetic Peak Torque Improvement and Shoulder Muscle Ratios Imbalance Correction After Specific Strength Training on a New Ballistic Throwing Device: A Randomized Controlled Trial},
journal = {Journal of Sport Rehabilitation},
year = {2024},
volume = {33},
number = {6},
pages = {423--436},
doi = {10.1123/jsr.2023-0253}
}
EUVIMED