EUVIMEDEUVIMED entdecken
Crossref

Do Movement Summary Metrics Produce Comparable Outputs Across Different Accelerometer Brands in Free Living?

Jimmy Duhamahoro, Paul R. Hibbing, Nicholas R. Lamoureux, Emily Berg, Gregory J. Welk

Journal for the Measurement of Physical Behaviour · 01.01.2026 · 9 (1)

DOI: 10.1123/jmpb.2025-0024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal for the Measurement of Physical Behaviour, erschienen am 01.01.2026. Verfasst von Jimmy Duhamahoro und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Various summary metrics have been proposed to standardize the processing of raw accelerometer data including the ActiGraph Counts (AC), Activity Index (AI), Euclidean Norm Minus One (ENMO), Mean Amplitude Deviation (MAD), Monitor-Independent Movement Summary Unit (MIMS), and Rate of Change Acceleration Movement (ROCAM).

Methods

Data were from the Free-Living Activity Study for Health, in which participants ( N = 78, age: 23.2 ± 8.4 years, 64% female, 87% white, body mass index: 24.4 ± 3.5 kg/m 2 ) wore an ActiGraph wGT3X-BT monitor on each wrist, plus GENEActiv and Axivity AX3 monitors (one on each wrist, counterbalanced for equal placements on dominant and nondominant sides). Participants wore devices for 24 hr and reported their physical activity via the Activities Completed over Time in 24 hr web survey. Summary metrics were obtained using open-source methods. The agreement was evaluated by equivalence testing (reference, ActiGraph) and Bland–Altman plots. The mean absolute percent error was calculated to assess relative individual errors.

Results

The AC, AI, and MIMS yielded 10% statistical equivalence across all brands. Trends were less consistent for ENMO, MAD, and ROCAM. Lowest overall mean absolute percent error was seen for MIMS (13.2 ± 16.7%), with higher values for AI (22.7 ± 50.5%), AC (25.1 ± 146.9%), ENMO (44.1 ± 79.2%), MAD (45.3 ± 66.3%), and ROCAM (98.5 ± 115.1%). Similar patterns were observed within specific intensities segmented by the Activities Completed over Time in 24 hr.

Conclusion

The results support the use of MIMS for device-agnostic physical behavior monitoring, whereas interdevice agreement was weaker for the other summary metrics.

Zitieren

APA

Duhamahoro, J., Hibbing, P. R., Lamoureux, N. R., Berg, E., & Welk, G. J. (2026). Do Movement Summary Metrics Produce Comparable Outputs Across Different Accelerometer Brands in Free Living?. Journal for the Measurement of Physical Behaviour, 9(1). https://doi.org/10.1123/jmpb.2025-0024

Vancouver

Duhamahoro J, Hibbing PR, Lamoureux NR, Berg E, Welk GJ. Do Movement Summary Metrics Produce Comparable Outputs Across Different Accelerometer Brands in Free Living?. Journal for the Measurement of Physical Behaviour. 2026;9(1). doi:10.1123/jmpb.2025-0024

BibTeX
@article{Duhamahoro2026,
  author = {Duhamahoro, Jimmy and Hibbing, Paul R. and Lamoureux, Nicholas R. and Berg, Emily and Welk, Gregory J.},
  title = {Do Movement Summary Metrics Produce Comparable Outputs Across Different Accelerometer Brands in Free Living?},
  journal = {Journal for the Measurement of Physical Behaviour},
  year = {2026},
  volume = {9},
  number = {1},
  doi = {10.1123/jmpb.2025-0024}
}
Kostenlos starten →