EUVIMEDEUVIMED entdecken
Crossref

Can Inertial Measurement Units Replace Common Sport Science Testing Equipment as an All-in-One Solution?

Drake Huff iD, Jacob Garrity, Daniel McIntosh iD, Robin Thorpe iD, Hugh Lamont iD, Jason Siegler iD

International Journal of Sports Physiology and Performance · 2026 · 1-4

DOI: 10.1123/ijspp.2026-0016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2026. Verfasst von Drake Huff und 5 weiteren Autor:innen. Beteiligte Einrichtung: Integrative Human Performance Lab, College of Health Solutions,Arizona State University, Phoenix, AZ, USA. Die Arbeit nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This pilot study evaluated the agreement between inertial measurement units (IMUs) and criterion standard performance assessment equipment (e.g., timing gates and force platforms).

Methods

Sixteen female Division 1 athletes completed a standard, preseason assessment battery including the 10-yard dash, Pro-Agility (5-10-5), countermovement jump, and a 5-3 multirebound jump wearing IMUs throughout the performance assessments to evaluate agreement with force platforms and timing gates. All testing took place in a climate-controlled collegiate weight room environment. Agreement between devices were evaluated separately for each assessment and measurement pair using repeated-measures limits of agreement analysis via the “SimplyAgree” package (v.0.2.1). Bias and limits of agreement were analyzed via method of variance estimates recovery with replicates selection applied.

Results

Inertial measurement units demonstrated a lack of agreement with criterion devices across all performance assessments (10-yard dash completion time, mean bias of −1.22 [0.29] s, and distance covered, mean bias of −4.09 [1.13] m); 5-10-5 completion time, mean bias of 0.80 [0.51] s, and distance covered, mean bias of 7.23 [1.56] m; countermovement jump height, mean bias of −13.12 [2.56] cm, and flight time, mean bias of −0.10 [0.02] s; and multirebound jump height, mean bias of −6.50 [2.65] cm).

Conclusions

Lack of agreement between IMUs and the criterion devices suggest that at present, IMUs should not be used as a single, expedient solution during performance testing.

Schlagwörter

Stichwörter der Autor:innen

force platformsperformance assessmenttiming gateswearables

Autor:innen und Institutionen

  • Integrative Human Performance Lab, College of Health Solutions,Arizona State University, Phoenix, AZ, USA.
  • Sun Devil Athletics,Arizona State University, Tempe, AZ, USA.
  • W.P. Carey School of Business, Arizona State University,Tempe,AZ, USA.
  • Department of Sport and Exercise Sciences, Institute of Sport, Manchester Metropolitan University, Manchester, United Kingdom.

ORCID-Profile: Drake Huff, Daniel McIntosh, Robin Thorpe, Hugh Lamont, Jason Siegler

Zitieren

APA

Huff, D., Garrity, J., McIntosh, D., Thorpe, R., Lamont, H., & Siegler, J. (2026). Can Inertial Measurement Units Replace Common Sport Science Testing Equipment as an All-in-One Solution?. International Journal of Sports Physiology and Performance, 1-4. https://doi.org/10.1123/ijspp.2026-0016

Vancouver

Huff D, Garrity J, McIntosh D, Thorpe R, Lamont H, Siegler J. Can Inertial Measurement Units Replace Common Sport Science Testing Equipment as an All-in-One Solution?. International Journal of Sports Physiology and Performance. 2026:1-4. doi:10.1123/ijspp.2026-0016

BibTeX
@article{Huff2026,
  author = {Huff, Drake and Garrity, Jacob and McIntosh, Daniel and Thorpe, Robin and Lamont, Hugh and Siegler, Jason},
  title = {Can Inertial Measurement Units Replace Common Sport Science Testing Equipment as an All-in-One Solution?},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2026},
  pages = {1--4},
  doi = {10.1123/ijspp.2026-0016}
}
Kostenlos starten →