Remote Ischemic Preconditioning Increases Maximal Accumulated Oxygen Deficit in Cross-Country Endurance Runners
International Journal of Sports Physiology and Performance · 2026 · 1-9
DOI: 10.1123/ijspp.2025-0640 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, 2026. Verfasst von Bryant R Byrd und 6 weiteren Autor:innen. Beteiligte Einrichtung: Recreation, Exercise & Sport Science Department,Western Colorado University, Gunnison, CO, USA. Die Arbeit nennt 61 Literaturangaben.
Abstract (Originalsprache)
Purpose
To test the hypothesis that remote ischemic preconditioning (IPC) improves severe intensity exercise performance in competitive cross-country endurance runners by increasing maximal accumulated oxygen deficit (AOD), an indicator of anaerobic capacity.
Methods
A randomized sham-controlled crossover study was employed in which 14 competitive trained male cross-country athletes (peak oxygen uptake [ ]: 62 [5] mL·kg −1 ·min −1 ) completed 3 maximal running trials (baseline, sham, remote IPC) at ∼110% to their limit of tolerance. Remote IPC was induced with 4 × 5-minute cycles of brachial artery occlusion with 5 minutes of reperfusion. Maximal AOD (in milliliters per kilogram) and oxygen uptake ( ) kinetics for each trial were derived from gas-exchange measures.
Results
Remote IPC (146 [58] s, 95% CI, 112–181) significantly increased the running limit of tolerance by 12% compared with baseline (131 [47] s, 95% CI, 102–160, P = .01), and 17% versus sham (125 [44] s, 95% CI, 96–154, P = .002). Likewise, with remote IPC, maximal AOD was 58.4 (12.2) mL/kg (95% CI, 51.3–65.5), a substantial increase compared with baseline (45.5 [9.1] mL/kg, P < .001, 95% CI, 40.3–50.8) and sham (46.4 [7.1] mL/kg, P = .01, 95% CI, 42.3–50.5). Analysis of kinetics revealed that remote IPC did not change the phase II time constant, but increased mean response time (17.6 [5.1] s) compared with baseline (15.5 [3.8] s, P = .014) and sham (15.8 [3.2] s, P = .04).
Conclusion
Remote IPC improved running performance in men cross-country athletes. Greater anaerobic capacity, as estimated by increased maximal AOD, may contribute to these performance improvements. Coaches and athletes may consider incorporating IPC into precompetition warm-ups to enhanced running tolerance and anaerobic capacity in trained runners.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Recreation, Exercise & Sport Science Department,Western Colorado University, Gunnison, CO, USA.
- Sports Performance Research Institute New Zealand,Auckland University of Technology, Auckland, New Zealand.
ORCID-Profile: Bryant R Byrd, Lance C Dalleck, Gary P Van Guilder, Andrew E Kilding
Zitieren
APA
Byrd, B. R., Sams, G. D., Walker, G. A., Lucero, M. A., Dalleck, L. C., Van Guilder, G. P., & Kilding, A. E. (2026). Remote Ischemic Preconditioning Increases Maximal Accumulated Oxygen Deficit in Cross-Country Endurance Runners. International Journal of Sports Physiology and Performance, 1-9. https://doi.org/10.1123/ijspp.2025-0640
Vancouver
Byrd BR, Sams GD, Walker GA, Lucero MA, Dalleck LC, Van Guilder GP, et al. Remote Ischemic Preconditioning Increases Maximal Accumulated Oxygen Deficit in Cross-Country Endurance Runners. International Journal of Sports Physiology and Performance. 2026:1-9. doi:10.1123/ijspp.2025-0640
BibTeX
@article{Byrd2026,
author = {Byrd, Bryant R and Sams, Gabriel D and Walker, Graydon A and Lucero, Marcus A and Dalleck, Lance C and Van Guilder, Gary P and Kilding, Andrew E},
title = {Remote Ischemic Preconditioning Increases Maximal Accumulated Oxygen Deficit in Cross-Country Endurance Runners},
journal = {International Journal of Sports Physiology and Performance},
year = {2026},
pages = {1--9},
doi = {10.1123/ijspp.2025-0640}
}
EUVIMED