EUVIMEDEUVIMED entdecken
Crossref

Running Power at Lactate Threshold and Lactate Turnpoint Are Unaltered by Treadmill Incline

Dami C Adejuwon, Robin Faricier, Daniel A Keir iD

International Journal of Sports Physiology and Performance · 01.07.2026 · 21 (7) · 815-823

DOI: 10.1123/ijspp.2025-0579 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Sports Physiology and Performance, erschienen am 01.07.2026. Verfasst von Dami C Adejuwon und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Kinesiology,The University of Western Ontario, London, ON, Canada. Hauptthemen laut MEDLINE: Running, Lactic Acid, Exercise Test, Anaerobic Threshold. Die Arbeit nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study investigated the effect of treadmill incline on wearable-derived running power output (rPO) at the lactate threshold (LT) and lactate turnpoint (LTP).

Methods

Thirteen trained runners (5 females; 23 [5] y) completed 3 rPO-matched, step-incremental treadmill tests to exhaustion at fixed inclines of 0%, 5%, and 10%. Running speed was adjusted to maintain consistent rPO across conditions using standardized calculations. During each test, breath-by-breath oxygen uptake ( ) and rPO (via Stryd power meter) were continuously measured. Blood lactate concentration was measured during the final 30 seconds of each 3-minute stage. The LT and LTP were identified from the blood lactate concentration versus rPO using 3-segment and modified-poly-D max fitting models, respectively. A repeated-measures analysis of variance assessed between-condition differences in LT and LTP ( P < .05).

Results

The –rPO relationship was not different across incline conditions ( P = .147). The rPO at LT did not differ between inclines ( P = .454): 259 (49) W, 252 (43) W, and 249 (56) W for 0%, 5%, and 10%, respectively, nor did rPO at LTP ( P = .604): 309 (58) W, 316 (59) W, and 312 (60) W for 0%, 5%, and 10%, respectively. The at LT ( P = .727) and LTP ( P = .470) also showed no significant differences across conditions.

Conclusion

The rPO at LT and LTP in highly trained runners are consistent across treadmill inclines between 0% and 10%. These findings support the use of rPO as a metric for monitoring exercise intensity across different gradient conditions in both training and performance settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningLactic AcidExercise TestAnaerobic ThresholdHumansFemaleOxygen ConsumptionYoung AdultMale

Stichwörter der Autor:innen

Strydblood lactateexercise intensity domainsoxygen uptakerunning performance

Substanzen

Lactic Acid

Autor:innen und Institutionen

  • School of Kinesiology,The University of Western Ontario, London, ON, Canada.
  • Toronto General Research Institute, Toronto General Hospital, Toronto, ON, Canada.
  • Lawson Health Research Institute, London, ON, Canada.

ORCID-Profile: Daniel A Keir

Zitieren

APA

Adejuwon, D. C., Faricier, R., & Keir, D. A. (2026). Running Power at Lactate Threshold and Lactate Turnpoint Are Unaltered by Treadmill Incline. International Journal of Sports Physiology and Performance, 21(7), 815-823. https://doi.org/10.1123/ijspp.2025-0579

Vancouver

Adejuwon DC, Faricier R, Keir DA. Running Power at Lactate Threshold and Lactate Turnpoint Are Unaltered by Treadmill Incline. International Journal of Sports Physiology and Performance. 2026;21(7):815-823. doi:10.1123/ijspp.2025-0579

BibTeX
@article{Adejuwon2026,
  author = {Adejuwon, Dami C and Faricier, Robin and Keir, Daniel A},
  title = {Running Power at Lactate Threshold and Lactate Turnpoint Are Unaltered by Treadmill Incline},
  journal = {International Journal of Sports Physiology and Performance},
  year = {2026},
  volume = {21},
  number = {7},
  pages = {815--823},
  doi = {10.1123/ijspp.2025-0579}
}
Kostenlos starten →