Mixed-Method Precooling Enhances Self-Paced 20-km Cycling Time-Trial Performance When Apparent Temperature Is >46 °C but May Not Be a Priority in
International Journal of Sports Physiology and Performance · 2024
DOI: 10.1123/ijspp.2023-0331 ↗Kurz gefasst
Mixed-Methods-Studie in der Zeitschrift International Journal of Sports Physiology and Performance, 2024. Verfasst von Julian Andro P Ramos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Curtin School of Allied Health, Curtin University, Perth, Australia. Hauptthemen laut MEDLINE: Bicycling, Athletic Performance, Body Temperature. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
Purpose
Precooling (PreC) may only benefit performance when thermal strain experienced by an individual is sufficiently high. We explored the effect of mixed-method PreC on 20-km cycling time-trial (CTT) performance under 3 different apparent temperatures (AT).
Methods
On separate days, 12 trained or highly trained male cyclists/triathletes completed six 20-km CTTs in 3 different ATs: hot-dry (35 °C AT), moderately hot-humid (40 °C AT), and hot-humid (46 °C AT). All trials were preceded by 30 minutes of mixed-method PreC or no PreC (control [CON]).
Results
Faster 2.5-km-split completion times occurred in PreC compared with CON in 46 °C AT ( P = .02), but not in 40 °C AT ( P = .62) or 35 °C AT ( P = .57). PreC did not affect rectal and body temperature during the 20-km CTT. Skin temperature was lower throughout the CTT in PreC compared with CON in 46 °C AT ( P = .01), but not in 40 °C AT ( P = 1.00) and 35 °C AT ( P = 1.00). Heart rate had a greater rate of increase during the CTT for PreC compared with CON in 46 °C AT ( P = .01), but not in 40 °C AT ( P = .57) and 35 °C AT ( P = 1.00). Ratings of perceived exertion ( P < .001) and thermal comfort ( P = .04) were lower for PreC compared with CON in 46 °C AT only, while thermal sensation was not different between PreC and CON.
Conclusion
Mixed-method PreC should be applied prior to 20-km CTTs conducted in hot-humid conditions (≥46 °C AT). Alternatively, mixed-method PreC may be a priority in moderately hot-humid (∼40 °C AT) conditions but should not be in hot-dry (∼35 °C AT) conditions for 20-km CTT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Curtin School of Allied Health, Curtin University, Perth, Australia.
- School of Human Sciences (Exercise and Sport Science), University of Western Australia, Perth, Australia.
ORCID-Profile: Julian Andro P Ramos, Kagan J Ducker, Hugh Riddell, Olivier Girard, Grant J Landers, Carly J Brade
Zitieren
APA
Ramos, J. A. P., Ducker, K. J., Riddell, H., Girard, O., Landers, G. J., & Brade, C. J. (2024). Mixed-Method Precooling Enhances Self-Paced 20-km Cycling Time-Trial Performance When Apparent Temperature Is >46 °C but May Not Be a Priority in. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2023-0331
Vancouver
Ramos JAP, Ducker KJ, Riddell H, Girard O, Landers GJ, Brade CJ. Mixed-Method Precooling Enhances Self-Paced 20-km Cycling Time-Trial Performance When Apparent Temperature Is >46 °C but May Not Be a Priority in. International Journal of Sports Physiology and Performance. 2024. doi:10.1123/ijspp.2023-0331
BibTeX
@article{Ramos2024,
author = {Ramos, Julian Andro P and Ducker, Kagan J and Riddell, Hugh and Girard, Olivier and Landers, Grant J and Brade, Carly J},
title = {Mixed-Method Precooling Enhances Self-Paced 20-km Cycling Time-Trial Performance When Apparent Temperature Is >46 °C but May Not Be a Priority in},
journal = {International Journal of Sports Physiology and Performance},
year = {2024},
doi = {10.1123/ijspp.2023-0331}
}
EUVIMED