A viscoelastic calibration procedure for orthogonal superposition rheometry
Journal of Rheology · 01.11.2026 · 70 (6) · 1471-1480
DOI: 10.1122/8.0001258 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Rheology, online erschienen am 29.10.2026. Verfasst von Jarno L. Waeterloos und 2 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Fonds Wetenschappelijk Onderzoek, Excellence of Science, Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Orthogonal superposition rheology is a powerful technique for probing the viscoelastic properties of complex materials under flow. However, its accuracy is heavily dependent on the precise calibration of four calibration parameters: the instrument’s transducer mass M, friction coefficient ζ, stiffness coefficient K, and geometry end-effects captured through the end-factor c⊥. This work demonstrates that the standard, decoupled calibration procedure, which utilizes static weights and Newtonian standards, can result in negative stiffness coefficients and nonminimum phase behavior, which are not representative for the experimental conditions when characterizing complex materials. The standard calibration also fails to account for the mathematical coupling between the friction coefficient and the orthogonal end-factor. In this paper, we demonstrate that, by exploiting the frequency-dependency of the moduli of a viscoelastic material, here different aqueous poly(ethylene)oxide solutions, the calibration offsets for the transducer mass, friction coefficient, and stiffness coefficient can be determined independently, together with the corresponding true orthogonal end-factor. Furthermore, the presence of the sample avoids the unstable behavior that occurs during the standard calibration methods. Validation of this novel calibration procedure across multiple rheometers with a polyisobutylene-CALTRAN solution shows that the proposed method performs equally to or better than traditional calibrations, particularly at high frequencies where instrument inertia dominates. This viscoelastic calibration procedure ensures a physically consistent calibration for the characterization of complex fluids.
Förderung
- Fonds Wetenschappelijk Onderzoek
- Excellence of Science
- Engineering and Physical Sciences Research Council
Zitieren
APA
Waeterloos, J. L., Curtis, D. J., & Clasen, C. (2026). A viscoelastic calibration procedure for orthogonal superposition rheometry. Journal of Rheology, 70(6), 1471-1480. https://doi.org/10.1122/8.0001258
Vancouver
Waeterloos JL, Curtis DJ, Clasen C. A viscoelastic calibration procedure for orthogonal superposition rheometry. Journal of Rheology. 2026;70(6):1471-1480. doi:10.1122/8.0001258
BibTeX
@article{Waeterloos2026,
author = {Waeterloos, Jarno L. and Curtis, Daniel J. and Clasen, Christian},
title = {A viscoelastic calibration procedure for orthogonal superposition rheometry},
journal = {Journal of Rheology},
year = {2026},
volume = {70},
number = {6},
pages = {1471--1480},
doi = {10.1122/8.0001258}
}
EUVIMED