EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Acoustic isolation of the Nasometer separation plate: Effects of plate geometry and microphone placement

Elan Little iD, Kaurab Gautam iD, Ephraim Gutmark iD, Liran Oren iD

The Journal of the Acoustical Society of America · 01.11.2026 · 160 (5) · 4176-4189

DOI: 10.1121/10.0047473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 12.11.2026. Verfasst von Elan Little und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering Education, MDE/IDES, Purdue University, West Lafayette, Indiana 47907, USA. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nasometers compute nasalance using microphones on each face of a rigid separation plate held at the philtrum. The manufacturer of the Pentax Nasometer specifies 25 dB of channel separation, but no methodological details accompany this value. This study quantifies acoustic isolation of the Nasometer separation plate from 100 to 7000 Hz, examining source amplitude, microphone position, and plate geometry. Tonal sweeps were performed in an anechoic chamber with microphones on each plate face. Within the 350–750 Hz nasalance band, the oral-to-nasal sound pressure level (SPL) difference (ΔSPL) for the clinical plate ranged from 10 to 15 dB, substantially below the manufacturer's specification. Leakage was largely level-independent, reflecting acoustic geometry rather than source amplitude. Moving the microphones to the lateral plate edge further reduced acoustic isolation, with ΔSPL falling to 6–12 dB. A larger custom plate at a matched microphone distance improved ΔSPL to 16–22.5 dB. Schlieren imaging with spectral proper orthogonal decomposition confirmed edge diffraction as the dominant leakage mechanism. For the clinical plate, the measured separations correspond to leakage nasalance contributions of approximately 15%–24%, overlapping published normative oral-speech scores and indicating plate-induced crosstalk is a clinically meaningful source of bias in nasalance measurements.

Autor:innen und Institutionen

  • School of Engineering Education, MDE/IDES, Purdue University, West Lafayette, Indiana 47907, USA.
  • Department of Aerospace Engineering and Engineering Mechanics, University of Cincinnati, Cincinnati, Ohio 45221, USA.
  • Department of Otolaryngology, University of Cincinnati, Cincinnati, Ohio 45267, USA.

ORCID-Profile: Elan Little, Kaurab Gautam, Ephraim Gutmark, Liran Oren

Zitieren

APA

Little, E., Gautam, K., Gutmark, E., & Oren, L. (2026). Acoustic isolation of the Nasometer separation plate: Effects of plate geometry and microphone placement. The Journal of the Acoustical Society of America, 160(5), 4176-4189. https://doi.org/10.1121/10.0047473

Vancouver

Little E, Gautam K, Gutmark E, Oren L. Acoustic isolation of the Nasometer separation plate: Effects of plate geometry and microphone placement. The Journal of the Acoustical Society of America. 2026;160(5):4176-4189. doi:10.1121/10.0047473

BibTeX
@article{Little2026,
  author = {Little, Elan and Gautam, Kaurab and Gutmark, Ephraim and Oren, Liran},
  title = {Acoustic isolation of the Nasometer separation plate: Effects of plate geometry and microphone placement},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {160},
  number = {5},
  pages = {4176--4189},
  doi = {10.1121/10.0047473}
}
Kostenlos starten →