EUVIMEDEUVIMED entdecken
VergleichsstudieEvaluationsstudie

A comparative evaluation of lab-generic and site-specific impulse response-based beamforming for enhanced automated bird call detection

Rifqi Ikhwanuddin iD, Neel P Le Penru iD, Sarab S Sethi iD, Lorenzo Picinali iD

The Journal of the Acoustical Society of America · 01.11.2026 · 160 (5) · 3754-3769

DOI: 10.1121/10.0046897 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 02.11.2026. Verfasst von Rifqi Ikhwanuddin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Dyson School of Design Engineering, Imperial College London, London, United Kingdom. Hauptthemen laut MEDLINE: Vocalization, Animal, Signal Processing, Computer-Assisted, Acoustics. Die Arbeit nennt 51 Literaturangaben. Gefördert von: Lembaga Pengelola Dana Pendidikan, LPDP.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automated ecoacoustic monitoring supports biodiversity conservation but struggles with signal degradation in noisy forests. Microphone-array recorders enable beamforming to focus on target directions and reduce background noise, yet their effectiveness in autonomous settings remains underexplored. This study evaluates filter-and-sum beamforming using measured impulse responses (IRs) to enhance bird-call classification. It compares lab-generic IRs from a semi-anechoic chamber with site-specific IRs measured in a forest. Playback experiments were conducted with a multichannel autonomous recorder using Eurasian blue tit calls in a real forest (1 to 64 m) and a 31-speaker virtual soundscape (signal-to-noise ratios from +30 to –30 dB). BirdNET performed classification, with metrics including detection count and confidence improvements versus the omnidirectional baseline. Both beamforming methods outperformed the baseline. Site-specific IR beamforming excelled at intermediate and long ranges. Both significantly raised confidence scores (p < 0.001), with site-specific IRs showing a modest advantage (mean Δ confidence 0.15 vs 0.11; p = 0.00001). These results confirm the value of beamforming for passive acoustic monitoring: site-specific IRs perform best, while lab-generic IRs provide a robust alternative for large-scale use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vocalization, AnimalSignal Processing, Computer-AssistedAcousticsAnimalsSound SpectrographyForestsNoiseTime FactorsAutomationSignal-To-Noise Ratio

Autor:innen und Institutionen

  • Dyson School of Design Engineering, Imperial College London, London, United Kingdom.
  • Engineering Physics, Faculty of Industrial Technology, Institut Teknologi Sumatera, Lampung, Indonesia.
  • Department of Life Sciences, Imperial College London, London, United Kingdom.

ORCID-Profile: Rifqi Ikhwanuddin, Neel P Le Penru, Sarab S Sethi, Lorenzo Picinali

Förderung

  • Lembaga Pengelola Dana Pendidikan, LPDP

Zitieren

APA

Ikhwanuddin, R., Le Penru, N. P., Sethi, S. S., & Picinali, L. (2026). A comparative evaluation of lab-generic and site-specific impulse response-based beamforming for enhanced automated bird call detection. The Journal of the Acoustical Society of America, 160(5), 3754-3769. https://doi.org/10.1121/10.0046897

Vancouver

Ikhwanuddin R, Le Penru NP, Sethi SS, Picinali L. A comparative evaluation of lab-generic and site-specific impulse response-based beamforming for enhanced automated bird call detection. The Journal of the Acoustical Society of America. 2026;160(5):3754-3769. doi:10.1121/10.0046897

BibTeX
@article{Ikhwanuddin2026,
  author = {Ikhwanuddin, Rifqi and Le Penru, Neel P and Sethi, Sarab S and Picinali, Lorenzo},
  title = {A comparative evaluation of lab-generic and site-specific impulse response-based beamforming for enhanced automated bird call detection},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {160},
  number = {5},
  pages = {3754--3769},
  doi = {10.1121/10.0046897}
}
Kostenlos starten →