Experimental and theoretical quantification of focused ultrasonic cavitation intensity

Xiaozhuo Shen iD, Jiawei Han iD, Pengfei Wu iD, Weijun Lin iD

The Journal of the Acoustical Society of America · 01.07.2026 · 160 (1) · 220-232

DOI: 10.1121/10.0044238 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 02.07.2026. Verfasst von Xiaozhuo Shen und 3 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Acoustics and Marine Information, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Institute of Microelectronics of the Chinese Academy of Sciences, Young Elite Scientists Sponsorship Program by Tianjin, Youth Innovation Promotion Association of the Chinese Academy of Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate characterization of ultrasonic cavitation is essential for safe and efficient ultrasound therapy. In this study, a synchronous acquisition system using a hydrophone and a high-speed camera was employed to observe the cavitation field generated by 994 kHz focused ultrasound within a power range of 20 W–400 W. Two quantitative indicators, the Broadband Integrated Pressure (BIP) and the image-gray-scale-based Cavitation State Variable (Q), were utilized to characterize the cavitation intensity. Theoretically, a computational method for cavitation intensity combining bubble cluster dynamics with an acoustic radiation model was proposed, establishing a quantitative analytical relationship between microscopic bubble dynamics and macroscopic cavitation intensity. The results indicate that the evolutionary trends of the experimentally measured BIP and Q with increasing driving power are highly consistent with the theoretical calculations, which demonstrated the effectiveness and complementary nature of the dual acoustic-optical evaluation system in quantifying cavitation intensity. This study clarifies the power-dependent mechanism of focused ultrasonic cavitation intensity, providing both a theoretical foundation and experimental support for precise cavitation control and dose optimization in clinical applications.

Autor:innen und Institutionen

  • State Key Laboratory of Acoustics and Marine Information, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China.
  • University of Chinese Academy of Sciences, Beijing 100049, China.

ORCID-Profile: Xiaozhuo Shen, Jiawei Han, Pengfei Wu, Weijun Lin

Förderung

  • Institute of Microelectronics of the Chinese Academy of Sciences
  • Young Elite Scientists Sponsorship Program by Tianjin
  • Youth Innovation Promotion Association of the Chinese Academy of Sciences

Zitieren

APA

Shen, X., Han, J., Wu, P., & Lin, W. (2026). Experimental and theoretical quantification of focused ultrasonic cavitation intensity. The Journal of the Acoustical Society of America, 160(1), 220-232. https://doi.org/10.1121/10.0044238

Vancouver

Shen X, Han J, Wu P, Lin W. Experimental and theoretical quantification of focused ultrasonic cavitation intensity. The Journal of the Acoustical Society of America. 2026;160(1):220-232. doi:10.1121/10.0044238

BibTeX
@article{Shen2026,
  author = {Shen, Xiaozhuo and Han, Jiawei and Wu, Pengfei and Lin, Weijun},
  title = {Experimental and theoretical quantification of focused ultrasonic cavitation intensity},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {160},
  number = {1},
  pages = {220--232},
  doi = {10.1121/10.0044238}
}
Kostenlos starten →