Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 14.05.2026. Verfasst von Jiahao Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Shaanxi Key Laboratory of Ultrasonics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China. Hauptthemen laut MEDLINE: Serum Albumin, Bovine, Sonication, Toluidines, Ultrasonics. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound is increasingly explored to regulate protein-small molecule interactions, yet the relative importance of acoustic parameters under practical liquid sonication remains unclear. This study used a bovine serum albumin-toluidine blue O (BSA-TBO) model system to quantify parameter-dependent spectroscopic responses after establishing a baseline binding state. A 20 kHz probe sonicator recorded changes in the fluorescence peak intensity of bovine serum albumin and BSA-TBO as a function of treatment time, ultrasonic power, and duty cycle, while a bath sonicator qualitatively compared peak-intensity responses at 25, 40, and 59 kHz. Temperature-matched heating controls, together with circular dichroism and synchronous fluorescence measurements, were used to test whether the parameter-dependent fluorescence response was dominated by bulk thermal effects. Under the present setup and geometry, ultrasonic power was the dominant factor; duty cycle and treatment time acted as secondary modulators via temporal delivery and cumulative exposure, whereas frequency effects were weaker and non-monotonic across the tested discrete points. These results provide guidance for parameter selection and optimization in ultrasound-regulated protein-ligand systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Serum Albumin, BovineSonicationToluidinesUltrasonicsUltrasonic WavesAnimalsCattleCircular DichroismProtein BindingSpectrometry, FluorescenceTime FactorsTemperature

Substanzen

Serum Albumin, BovineToluidines

Autor:innen und Institutionen

  • Shaanxi Key Laboratory of Ultrasonics, School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China.
  • College of Science, China Jiliang University, Hangzhou 310018, China.

ORCID-Profile: Fengming Li

Zitieren

APA

Li, J., Chen, S., Zheng, C., Chang, Y., Zhou, D., Li, F., & Hao, C. (2026). Dependence of ultrasonic parameters on bovine serum albumin-toluidine blue O binding: A spectroscopic analysis. The Journal of the Acoustical Society of America, 159(5), 4088-4096. https://doi.org/10.1121/10.0043879

Vancouver

Li J, Chen S, Zheng C, Chang Y, Zhou D, Li F, et al. Dependence of ultrasonic parameters on bovine serum albumin-toluidine blue O binding: A spectroscopic analysis. The Journal of the Acoustical Society of America. 2026;159(5):4088-4096. doi:10.1121/10.0043879

BibTeX
@article{Li2026,
  author = {Li, Jiahao and Chen, Shiwei and Zheng, Chennan and Chang, Yijin and Zhou, Dazhi and Li, Fengming and Hao, Changchun},
  title = {Dependence of ultrasonic parameters on bovine serum albumin-toluidine blue O binding: A spectroscopic analysis},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {159},
  number = {5},
  pages = {4088--4096},
  doi = {10.1121/10.0043879}
}
Kostenlos starten →