Binaural sensitivity and processing of envelope-based interaural difference cues by bilateral cochlear implant users with perilingual and postlingual onset of deafness
The Journal of the Acoustical Society of America · 01.04.2026 · 159 (4) · 3464-3475
DOI: 10.1121/10.0043466 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 20.04.2026. Verfasst von Z Ellen Peng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Waisman Center, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, Wisconsin 53705, USA. Hauptthemen laut MEDLINE: Cues, Cochlear Implants, Sound Localization, Cochlear Implantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCD NIH HHS, NICHD NIH HHS, Foundation for the National Institutes of Health.
Abstract (Originalsprache)
Cochlear implants deliver binaural cues primarily in the signal envelope through two unsynchronized sound processors, presenting challenges to bilateral cochlear implant (BiCI) users to (re)gain binaural hearing. Using a custom-designed acoustic complex to elicit multi-channel stimulation through the cochlear implant sound processors, this study measured sensitivity to interaural time difference (ITD) and interaural level difference (ILD) using a discrimination task while concurrently tracking eye gaze positions to reveal decision-making delays during binaural processing. Two groups of BiCI users were tested with either perilingual or postlingual onset of deafness. Results show all BiCI users exhibited ILD sensitivity and a majority (67% of the perilingual and 78% of the postlingual) demonstrated ITD sensitivity, though those with perilingual onset showed higher (poorer) ITD sensitivity compared to postlingual users. Additionally, ILD processing at suprathreshold magnitudes led to faster decision making as accuracy increased for both groups. However, ITD processing was less salient, with faster ITD processing observed only in the postlingual group. These findings provide insights into the differences in binaural processing in users based on the timing of deafness onset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Waisman Center, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, Wisconsin 53705, USA.
ORCID-Profile: Z Ellen Peng, Alan Kan, Ruth Y Litovsky
Förderung
- NIDCD NIH HHS
- NICHD NIH HHS
- Foundation for the National Institutes of Health
Zitieren
APA
Peng, Z. E., Kan, A., & Litovsky, R. Y. (2026). Binaural sensitivity and processing of envelope-based interaural difference cues by bilateral cochlear implant users with perilingual and postlingual onset of deafness. The Journal of the Acoustical Society of America, 159(4), 3464-3475. https://doi.org/10.1121/10.0043466
Vancouver
Peng ZE, Kan A, Litovsky RY. Binaural sensitivity and processing of envelope-based interaural difference cues by bilateral cochlear implant users with perilingual and postlingual onset of deafness. The Journal of the Acoustical Society of America. 2026;159(4):3464-3475. doi:10.1121/10.0043466
BibTeX
@article{Peng2026,
author = {Peng, Z Ellen and Kan, Alan and Litovsky, Ruth Y},
title = {Binaural sensitivity and processing of envelope-based interaural difference cues by bilateral cochlear implant users with perilingual and postlingual onset of deafness},
journal = {The Journal of the Acoustical Society of America},
year = {2026},
volume = {159},
number = {4},
pages = {3464--3475},
doi = {10.1121/10.0043466}
}
EUVIMED