EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance of a through-transmit aberration correction method for transcranial focused ultrasound: Simulation and experimental evaluation

Cooper L Donovan iD, Charles F Caskey iD

The Journal of the Acoustical Society of America · 01.03.2026 · 159 (3) · 2694-2705

DOI: 10.1121/10.0043031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 23.03.2026. Verfasst von Cooper L Donovan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA. Hauptthemen laut MEDLINE: Skull, Computer Simulation. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, Acoustical Society of America, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcranial focused ultrasound is a promising neuromodulation tool, but skull-induced aberrations to the ultrasound beam require subject-specific correction. To predict and compensate for aberration, the standard in transcranial focused ultrasound is to perform acoustic simulations based on x-ray computed tomography images of the head. However, computed tomography-based methods face shortcomings due to imaging resolution and uncertainty in acoustic parameter estimates. Relativistic through-transmit (RTT) is a recently proposed imaging-independent method that corrects skull-induced aberrations by comparing through-skull acoustic transmission to free-field signals from two opposing transducer arrays. Although RTT has shown promise, its robustness across subjects and conditions has not been fully characterized. In this work, RTT performance was evaluated in simulation as a function of several parameters in four unique non-human primate subjects using commercial linear phased array transducers operating at 1 and 2 MHz. Simulated results were validated experimentally at 2 MHz. In simulations, RTT restored pressure amplitudes to within 5% of the intended value for three skulls but achieved only 60% of the intended pressure in one, with focal shift ranging 0.4 to 5.5 mm. RTT performance depended on signal-to-noise ratio and physical uncertainties and was markedly impacted by steering. Modifications to RTT are proposed and characterized.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SkullComputer SimulationAnimalsTransducersPressureSignal Processing, Computer-Assisted

Autor:innen und Institutionen

  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee 37232, USA.

ORCID-Profile: Cooper L Donovan, Charles F Caskey

Förderung

  • NINDS NIH HHS
  • Acoustical Society of America
  • National Institutes of Health

Zitieren

APA

Donovan, C. L., & Caskey, C. F. (2026). Performance of a through-transmit aberration correction method for transcranial focused ultrasound: Simulation and experimental evaluation. The Journal of the Acoustical Society of America, 159(3), 2694-2705. https://doi.org/10.1121/10.0043031

Vancouver

Donovan CL, Caskey CF. Performance of a through-transmit aberration correction method for transcranial focused ultrasound: Simulation and experimental evaluation. The Journal of the Acoustical Society of America. 2026;159(3):2694-2705. doi:10.1121/10.0043031

BibTeX
@article{Donovan2026,
  author = {Donovan, Cooper L and Caskey, Charles F},
  title = {Performance of a through-transmit aberration correction method for transcranial focused ultrasound: Simulation and experimental evaluation},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  volume = {159},
  number = {3},
  pages = {2694--2705},
  doi = {10.1121/10.0043031}
}