EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluating a cochlear transducer function and its operating point from low-frequency modulated distortion-product otoacoustic emissions simulated in a cochlear model

Aleš Vetešník, Anthony W Gummer iD, Václav Vencovský iD

The Journal of the Acoustical Society of America · 2026

DOI: 10.1121/10.0041859 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, 2026. Verfasst von Aleš Vetešník und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Chemistry, Czech Technical University in Prague, Prague 115 19, Czech Republic. Hauptthemen laut MEDLINE: Cochlea, Otoacoustic Emissions, Spontaneous, Models, Biological, Computer Simulation. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Grantová Agentura České Republiky.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Distortion-product otoacoustic emission (DPOAE) offers a noninvasive objective diagnosis of the functional state of the cochlear amplifier. Bian, Chertoff, and Miller [J. Acoust. Soc. Am. 112, 198–210 (2002)] proposed a technique for estimating a cochlear transducer function from DPOAEs modulated by a low-frequency (LF) high-intensity bias tone. It was assumed that DPOAE generation is defined by a single nonlinearity driven directly by the input pressure in the ear canal and maintained that for low-intensity primary tones, the lower cubic (2f1−f2) and quadratic (f2−f1) components of DPOAEs are proportional to the third and second derivatives, respectively, of the proposed transducer function. Here, a two-dimensional nonlinear model of the human cochlea is employed to simulate and analyze the bias-tone experiments performed by Bian et al. and others. Using our model, it is shown that modulation of the time course of the DPOAE signal by the bias tone is not directly related to the third or second derivatives of the transducer function. Instead, it is observed that those changes significantly depend on the decrease in the amplitude of the basilar membrane responses at the primary tone frequencies and on the distribution of DPOAE sources. An alternative interpretation of DPOAE amplitude modulation by a LF bias tone is proposed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CochleaOtoacoustic Emissions, SpontaneousModels, BiologicalComputer SimulationHumansNonlinear DynamicsAcoustic StimulationTime Factors

Autor:innen und Institutionen

  • Department of Nuclear Chemistry, Czech Technical University in Prague, Prague 115 19, Czech Republic.
  • Department of Otolaryngology, Eberhard-Karls University Tübingen, Tübingen 72076, Germany.
  • Department of Radio Engineering, Czech Technical University in Prague, Prague 166 27, Czech Republic.

ORCID-Profile: Anthony W Gummer, Václav Vencovský

Förderung

  • Grantová Agentura České Republiky

Zitieren

APA

Vetešník, A., Gummer, A. W., & Vencovský, V. (2026). Evaluating a cochlear transducer function and its operating point from low-frequency modulated distortion-product otoacoustic emissions simulated in a cochlear model. The Journal of the Acoustical Society of America. https://doi.org/10.1121/10.0041859

Vancouver

Vetešník A, Gummer AW, Vencovský V. Evaluating a cochlear transducer function and its operating point from low-frequency modulated distortion-product otoacoustic emissions simulated in a cochlear model. The Journal of the Acoustical Society of America. 2026. doi:10.1121/10.0041859

BibTeX
@article{Vetenk2026,
  author = {Vetešník, Aleš and Gummer, Anthony W and Vencovský, Václav},
  title = {Evaluating a cochlear transducer function and its operating point from low-frequency modulated distortion-product otoacoustic emissions simulated in a cochlear model},
  journal = {The Journal of the Acoustical Society of America},
  year = {2026},
  doi = {10.1121/10.0041859}
}
Kostenlos starten →