EUVIMEDEUVIMED entdecken
Crossref

Sensor-free ultrasound image-based registration system for liver tumor treatment assessment

Riku Kasagi, Norihiro Koizumi, Kazushi Numata

The Journal of the Acoustical Society of America · 01.10.2025 · 158 (4_Supplement) · A426-A426

DOI: 10.1121/10.0041382 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, erschienen am 01.10.2025. Verfasst von Riku Kasagi und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In minimally invasive liver tumor treatment without laparotomy, accurate registration between pre- and post-treatment images is essential for evaluating therapeutic effectiveness. Although contrast-enhanced ultrasound is increasingly used postoperatively due to its real-time capability, aligning it precisely with pre-treatment 3-D images remains challenging. Conventional methods often rely on magnetic sensors, which are costly and complex. Hence, a simpler and more affordable sensor-free method is needed. We propose a registration system that uses only ultrasound imaging, a common acoustic diagnostic tool. Before treatment, a robotically controlled probe scans the abdomen, and a 3-D vascular model is built from vessels visualized in ultrasound. Cross-sectional images in various orientations are generated from this model and used to train a deep-learning model. Post-treatment ultrasound images undergo vessel extraction, and the trained model estimates their acquisition positions. Based on this, initial alignment is performed with the 3-D model, followed by rigid point cloud registration to refine it. In evaluations using an abdominal phantom, 85.2% of 3000 test images were registered within a 10-mm error. Average processing time per image was 0.0782 s, demonstrating feasibility for real-time use. This method leverages the real-time nature of ultrasound, offering a promising sensor-free approach for convenient evaluation of therapeutic effectiveness.

Zitieren

APA

Kasagi, R., Koizumi, N., & Numata, K. (2025). Sensor-free ultrasound image-based registration system for liver tumor treatment assessment. The Journal of the Acoustical Society of America, 158(4_Supplement), A426-A426. https://doi.org/10.1121/10.0041382

Vancouver

Kasagi R, Koizumi N, Numata K. Sensor-free ultrasound image-based registration system for liver tumor treatment assessment. The Journal of the Acoustical Society of America. 2025;158(4_Supplement):A426-A426. doi:10.1121/10.0041382

BibTeX
@article{Kasagi2025,
  author = {Kasagi, Riku and Koizumi, Norihiro and Numata, Kazushi},
  title = {Sensor-free ultrasound image-based registration system for liver tumor treatment assessment},
  journal = {The Journal of the Acoustical Society of America},
  year = {2025},
  volume = {158},
  number = {4_Supplement},
  pages = {A426--A426},
  doi = {10.1121/10.0041382}
}
Kostenlos starten →