EUVIMEDEUVIMED entdecken
Crossref

Comparing slow-flow sensitivity in vivo between superharmonic and conventional ultrasound localization microscopy

Kathlyne Jayne Bautista, Jadyn Cook, Francisco Santibanez, Gianmarco Pinton, Paul A. Dayton

The Journal of the Acoustical Society of America · 01.10.2025 · 158 (4_Supplement) · A375-A376

DOI: 10.1121/10.0041205 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, erschienen am 01.10.2025. Verfasst von Kathlyne Jayne Bautista und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound localization microscopy (ULM) is a microvasculature imaging technique that can resolve vessels beyond the diffraction limit. A key step is the separation of microbubbles (MB) from tissue. Conventional ULM uses spatiotemporal filters, such as Singular Value Decomposition (SVD), that are insensitive to slow flow and easily degraded by motion. Superharmonic (SpH) imaging addresses these limitations by leveraging the nonlinear physics of MB interaction to separate the signals in the frequency domain while preserving slow and stationary flow. The slow-flow sensitivity of SpH ULM is compared with conventional ULM. Simultaneous 2-D SpH and 2-D B-mode images were acquired continuously at a frame rate of 400 Hz in an internal kidney, in a freely breathing rodent. Each acquisition contained 120 000 frames. MB localization and tracking were performed on SpH and SVD-filtered B-mode frames (with a singular value cutoff of 200/1000). Velocities and track counts were compared in manually segmented kidney regions. SpH ULM generated 13 and 2600 times more slow tracks (per unit area) ( < 10 mm/s) in the cortex and medulla, respectively, than conventional ULM. The mean slow track velocity in the cortex was additionally lower in SpH ULM. Conversely, conventional ULM resolved 26 times more fast tracks (10–30 mm/s) in the cortex. These results highlight the enhanced sensitivity of SpH imaging for slow-flow ULM (with a potential fast-flow tradeoff) toward future applications in kidney glomerular and tumor imaging.

Zitieren

APA

Bautista, K. J., Cook, J., Santibanez, F., Pinton, G., & Dayton, P. A. (2025). Comparing slow-flow sensitivity in vivo between superharmonic and conventional ultrasound localization microscopy. The Journal of the Acoustical Society of America, 158(4_Supplement), A375-A376. https://doi.org/10.1121/10.0041205

Vancouver

Bautista KJ, Cook J, Santibanez F, Pinton G, Dayton PA. Comparing slow-flow sensitivity in vivo between superharmonic and conventional ultrasound localization microscopy. The Journal of the Acoustical Society of America. 2025;158(4_Supplement):A375-A376. doi:10.1121/10.0041205

BibTeX
@article{Bautista2025,
  author = {Bautista, Kathlyne Jayne and Cook, Jadyn and Santibanez, Francisco and Pinton, Gianmarco and Dayton, Paul A.},
  title = {Comparing slow-flow sensitivity in vivo between superharmonic and conventional ultrasound localization microscopy},
  journal = {The Journal of the Acoustical Society of America},
  year = {2025},
  volume = {158},
  number = {4_Supplement},
  pages = {A375--A376},
  doi = {10.1121/10.0041205}
}
Kostenlos starten →