EUVIMEDEUVIMED entdecken
Crossref

Measurement and compensation of discrepancy in sound source direction perceived through bone-conduction headphones for audible pure tones

Mamoru Iwaki, Riki Sato

The Journal of the Acoustical Society of America · 01.10.2025 · 158 (4_Supplement) · A249-A249

DOI: 10.1121/10.0040770 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, erschienen am 01.10.2025. Verfasst von Mamoru Iwaki und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bone conduction (BC) headphones are reportedly more centered in the perceived direction of the sound source than air conduction (AC) headphones [Autumn Mtg Acoust. Soc. Japan, 3-1-18, pp. 865–866, 2013; IEEE Int’l Conf. GCCE, pp. 887–888, 2021], thereby undermining the advantages of BC headphones as hearing aids. However, the prior reports were limited to pure tones between 500 and 4,000 Hz. In the present study, we newly report the directional differences in sound stimulation by BC headphones over a wide frequency range of 125–16 000 Hz and propose a compensation method that emphasizes ILD. In the listening experiment, sound stimuli were presented separately with AC and BC headphones (SONY MDR-1R and TEAC Filltune HP-F200) with the sound pressure level (SPL) of 60 dB SPL. Appropriate ILD and ITD were added for each stimuli. SPL through the BC headphone was adjusted to have the same loudness for each participant, and participants then judged the direction of the sound. Although the direction perceived through the BC headphones was still closer to the center, even over a wide frequency range, our proposed compensation method could effectively mitigate this problem. [Work supported by JSPS KAKENHI grant no. JP23K11180.]

Zitieren

APA

Iwaki, M., & Sato, R. (2025). Measurement and compensation of discrepancy in sound source direction perceived through bone-conduction headphones for audible pure tones. The Journal of the Acoustical Society of America, 158(4_Supplement), A249-A249. https://doi.org/10.1121/10.0040770

Vancouver

Iwaki M, Sato R. Measurement and compensation of discrepancy in sound source direction perceived through bone-conduction headphones for audible pure tones. The Journal of the Acoustical Society of America. 2025;158(4_Supplement):A249-A249. doi:10.1121/10.0040770

BibTeX
@article{Iwaki2025,
  author = {Iwaki, Mamoru and Sato, Riki},
  title = {Measurement and compensation of discrepancy in sound source direction perceived through bone-conduction headphones for audible pure tones},
  journal = {The Journal of the Acoustical Society of America},
  year = {2025},
  volume = {158},
  number = {4_Supplement},
  pages = {A249--A249},
  doi = {10.1121/10.0040770}
}
Kostenlos starten →