Phase coherence of cochlear microphonic potentials in cochlear implant users with ipsilateral residual hearing
The Journal of the Acoustical Society of America · 2026
DOI: 10.1121/10.0039540 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, 2026. Verfasst von Benjamin Krüger und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Carl-Neuberg-Straße 1, 30625 Hannover, Germany. Hauptthemen laut MEDLINE: Cochlear Implants, Cochlear Microphonic Potentials, Cochlear Implantation, Persons with Hearing Disabilities. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HORIZON EUROPE European Research Council.
Abstract (Originalsprache)
Intracochlear recorded growth functions of cochlear potentials evoked by acoustic tones were analyzed by their phase coherence, variance, and density distribution. Potentials obtained from electrocochleography recorded in cochlear implant users with ipsilateral residual hearing were analyzed in the complex domain. The study shows that (1) the phase of the cochlear microphonic (CM) is coherent across stimulation levels, (2) CM potentials are circularly symmetric normally distributed in the complex domain, regardless of stimulation level or response amplitude, and (3) the variance of CM potentials remains consistent, irrespective of stimulation level. Based on these findings, we introduce a method that utilizes the phase coherence across stimulation levels to improve the accuracy of CM amplitude estimates, particularly when amplitudes are close to the noise floor. A key aspect of this method is addressing the bias introduced by the circularly symmetric normal distribution of additive Gaussian noise in the complex domain, which can lead to overestimation of signal magnitude. The results show that phase coherence can be used to enhance the accuracy of amplitude estimates of cochlear potentials, thereby making the recording process more efficient. Furthermore, the consistent variance of cochlear potentials enables noise estimations from recordings containing receptor potentials, independent of the stimulation level.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Otolaryngology, Hannover Medical School, Cluster of Excellence Hearing4all, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.
- Institute of Neuroscience and the Department of Microelectronics and Systems Electronics, Universitat Autònoma de Barcelona, 08193 Barcelona, Spain.
Förderung
- HORIZON EUROPE European Research Council
Zitieren
APA
Krüger, B., & Nogueira, W. (2026). Phase coherence of cochlear microphonic potentials in cochlear implant users with ipsilateral residual hearing. The Journal of the Acoustical Society of America. https://doi.org/10.1121/10.0039540
Vancouver
Krüger B, Nogueira W. Phase coherence of cochlear microphonic potentials in cochlear implant users with ipsilateral residual hearing. The Journal of the Acoustical Society of America. 2026. doi:10.1121/10.0039540
BibTeX
@article{Krger2026,
author = {Krüger, Benjamin and Nogueira, Waldo},
title = {Phase coherence of cochlear microphonic potentials in cochlear implant users with ipsilateral residual hearing},
journal = {The Journal of the Acoustical Society of America},
year = {2026},
doi = {10.1121/10.0039540}
}
EUVIMED