Digital twins enable full-reference quality assessment of photoacoustic image reconstructions
The Journal of the Acoustical Society of America · 01.07.2025 · 158 (1) · 590-601
DOI: 10.1121/10.0037188 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 23.07.2025. Verfasst von Janek Gröhl und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, University of Cambridge, Cambridge, United Kingdom. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Directorate for Mathematical and Physical Sciences, Cancer Research UK Cambridge Institute, University of Cambridge.
Abstract (Originalsprache)
Quantitative comparison of the quality of photoacoustic image reconstruction algorithms remains a major challenge. No-reference image quality measures are often inadequate, but full-reference measures require access to an ideal reference image. While the ground truth is known in simulations, it is unknown in vivo or in phantom studies, as the reference depends on both the phantom properties and the imaging system. This paper tackles this problem by using numerical digital twins of tissue-mimicking phantoms and the imaging system to perform a quantitative calibration to reduce the simulation gap. The contributions of this paper are twofold: First, this digital-twin framework is used to compare multiple state-of-the-art reconstruction algorithms. Second, among these is a Fourier transform-based reconstruction algorithm for circular detection geometries, which is tested on experimental data for the first time. The results demonstrate the usefulness of digital phantom twins by enabling assessment of the accuracy of the numerical forward model and enabling comparison of image reconstruction schemes with full-reference image quality assessment. This paper shows that the Fourier transform-based algorithm yields results comparable to those of iterative time reversal, but at a lower computational cost.
Autor:innen und Institutionen
- Department of Physics, University of Cambridge, Cambridge, United Kingdom.
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, United Kingdom.
- ENI-G, a Joint Initiative of the University Medical Center Göttingen and the Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
- Department of Mathematics, University of Arizona, Tucson, Arizona 85721, USA.
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.
- Department of Bioengineering, Imperial College London, London, United Kingdom.
ORCID-Profile: Janek Gröhl, Leonid Kunyansky, Jenni Poimala, Thomas R Else, Sarah E Bohndiek, Ben T Cox, Andreas Hauptmann
Förderung
- Deutsche Forschungsgemeinschaft
- Directorate for Mathematical and Physical Sciences
- Cancer Research UK Cambridge Institute, University of Cambridge
- Academy of Finland
- HORIZON EUROPE European Research Council
- Finnish Ministry of Education and Culture's Pilot for Doctoral Programmes
- Engineering and Physical Sciences Research Council
Zitieren
APA
Gröhl, J., Kunyansky, L., Poimala, J., Else, T. R., Di Cecio, F., Bohndiek, S. E., Cox, B. T., & Hauptmann, A. (2025). Digital twins enable full-reference quality assessment of photoacoustic image reconstructions. The Journal of the Acoustical Society of America, 158(1), 590-601. https://doi.org/10.1121/10.0037188
Vancouver
Gröhl J, Kunyansky L, Poimala J, Else TR, Di Cecio F, Bohndiek SE, et al. Digital twins enable full-reference quality assessment of photoacoustic image reconstructions. The Journal of the Acoustical Society of America. 2025;158(1):590-601. doi:10.1121/10.0037188
BibTeX
@article{Grhl2025,
author = {Gröhl, Janek and Kunyansky, Leonid and Poimala, Jenni and Else, Thomas R and Di Cecio, Francesca and Bohndiek, Sarah E and Cox, Ben T and Hauptmann, Andreas},
title = {Digital twins enable full-reference quality assessment of photoacoustic image reconstructions},
journal = {The Journal of the Acoustical Society of America},
year = {2025},
volume = {158},
number = {1},
pages = {590--601},
doi = {10.1121/10.0037188}
}
EUVIMED