Frequency-differencing strategy to kickstart full-waveform inversion without cycle skipping
JASA Express Letters · 01.01.2025 · 5 (1)
DOI: 10.1121/10.0034763 ↗Kurz gefasst
Fachartikel in der Zeitschrift JASA Express Letters, online erschienen am 03.01.2025. Verfasst von Rehman Ali und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging Sciences, University of Rochester, Rochester, New York 14642, USA. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Ultrasound tomography fundamentally relies on low-frequency data to avoid cycle skipping in full-waveform inversion (FWI). In the absence of sufficiently low-frequency data, we can extrapolate low-frequency content from existing high-frequency signals by using the same approach used in frequency-difference beamforming. This low-frequency content is then used to kickstart FWI and avoid cycle skipping at higher frequencies. In simulations, the structural similarity index measure and peak signal-to-noise ratio of the reconstructed image improve by 0.28 and 8.6 dB, respectively, as a result of frequency differencing. Experiments show that internal structures can be seen with greater clarity because of frequency differencing.
Autor:innen und Institutionen
- Department of Imaging Sciences, University of Rochester, Rochester, New York 14642, USA.
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York 14642, USA.
- Department of Neuroscience, University of Rochester, Rochester, New York 14642, USARehman_Ali@URMC.Rochester.edu, Trevor_Mitcham@URMC.Rochester.edu, iowolabi@UR.Rochester.edu, Sarah_McConnell@URMC.Rochester.edu, Nebojsa…
ORCID-Profile: Rehman Ali
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Ali, R., Mitcham, T., Owolabi, I., McConnell, S., & Duric, N. (2025). Frequency-differencing strategy to kickstart full-waveform inversion without cycle skipping. JASA Express Letters, 5(1). https://doi.org/10.1121/10.0034763
Vancouver
Ali R, Mitcham T, Owolabi I, McConnell S, Duric N. Frequency-differencing strategy to kickstart full-waveform inversion without cycle skipping. JASA Express Letters. 2025;5(1). doi:10.1121/10.0034763
BibTeX
@article{Ali2025,
author = {Ali, Rehman and Mitcham, Trevor and Owolabi, Israel and McConnell, Sarah and Duric, Nebojsa},
title = {Frequency-differencing strategy to kickstart full-waveform inversion without cycle skipping},
journal = {JASA Express Letters},
year = {2025},
volume = {5},
number = {1},
doi = {10.1121/10.0034763}
}
EUVIMED