EUVIMEDEUVIMED entdecken
Crossref

Cortical bone plate properties assessment using inversion of axially transmitted low frequency ultrasonic guided waves

Aubin Chaboty iD, Vu-Hieu Nguyen iD, Guillaume Haiat iD, Pierre Bélanger iD

The Journal of the Acoustical Society of America · 01.08.2024 · 156 (2) · 954-967

DOI: 10.1121/10.0028173 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 12.08.2024. Verfasst von Aubin Chaboty und 3 weiteren Autor:innen. Beteiligte Einrichtung: PULETS, École de Technologie Supérieure, Montréal, Québec, Canada. Hauptthemen laut MEDLINE: Phantoms, Imaging, Cortical Bone, Ultrasonography. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 71 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past few decades, early osteoporosis detection using ultrasonic bone quality evaluation has gained prominence. Specifically, various studies focused on axial transmission using ultrasonic guided waves and have highlighted this technique's sensitivity to intrinsic properties of long cortical bones. This work aims to demonstrate the potential of low-frequency ultrasonic guided waves to infer the properties of the bone inside which they are propagating. A proprietary ultrasonic transducer, tailored to transmit ultrasonic guided waves under 500 kHz, was used for the data collection. The gathered data underwent two-dimensional fast Fourier transform processing to extract experimental dispersion curves. The proposed inversion scheme compares experimental dispersion curves with simulated dispersion curves calculated through the semi-analytical iso-geometric analysis (SAIGA) method. The numerical model integrates a bone phantom plate coupled with a soft tissue layer on its top surface, mimicking the experimental bone phantom plates. Subsequently, the mechanical properties of the bone phantom plates were estimated by reducing the misfit between the experimental and simulated dispersion curves. This inversion leaned heavily on the dispersive trajectories and amplitudes of ultrasonic guided wave modes. Results indicate a marginal discrepancy under 5% between the mechanical properties ascertained using the SAIGA-based inversion and those measured using bulk wave pulse-echo measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingCortical BoneUltrasonographyFourier AnalysisUltrasonic WavesHumansTransducersNumerical Analysis, Computer-AssistedComputer Simulation

Autor:innen und Institutionen

  • PULETS, École de Technologie Supérieure, Montréal, Québec, Canada.
  • MSME, CNRS, UMR 8208, Université Paris Est Créteil, Université Gustave Eiffel, F-94010 Créteil, France.
  • MSME, CNRS, UMR 8208, F-94010 Créteil, France.

ORCID-Profile: Aubin Chaboty, Vu-Hieu Nguyen, Guillaume Haiat, Pierre Bélanger

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Chaboty, A., Nguyen, V. H., Haiat, G., & Bélanger, P. (2024). Cortical bone plate properties assessment using inversion of axially transmitted low frequency ultrasonic guided waves. The Journal of the Acoustical Society of America, 156(2), 954-967. https://doi.org/10.1121/10.0028173

Vancouver

Chaboty A, Nguyen VH, Haiat G, Bélanger P. Cortical bone plate properties assessment using inversion of axially transmitted low frequency ultrasonic guided waves. The Journal of the Acoustical Society of America. 2024;156(2):954-967. doi:10.1121/10.0028173

BibTeX
@article{Chaboty2024,
  author = {Chaboty, Aubin and Nguyen, Vu-Hieu and Haiat, Guillaume and Bélanger, Pierre},
  title = {Cortical bone plate properties assessment using inversion of axially transmitted low frequency ultrasonic guided waves},
  journal = {The Journal of the Acoustical Society of America},
  year = {2024},
  volume = {156},
  number = {2},
  pages = {954--967},
  doi = {10.1121/10.0028173}
}
Kostenlos starten →